Net ‘N’ Clean In Floor Cleaning Systems v09-20
7
Nozzle
Setting
Combination
m
3
/h
lpm
Legth of
water jet
S1
B + D
2
33.3
0.5 m
S2
A + D
3
50.0
1.0 m
S3
B + C
4
66.7
1.5 m
S4
A + C
5
83.3
1.8 m
Flow Rate
INSTALLATION REQUIREMENTS
FLOW RATES
The Astral Pool Net ‘N’ Clean infloor system requires a minimum flow rate of 8 cubic metres per hour (133 lpm) and has a
maximum allowable flow rate of 25 cubic metres per hour (417 lpm). The operation of the distributor valve is based on flow
through the turbine and is not dependant on pressure. A larger pump will not automatically correct an issue with flow.
The combined flow through the nozzles on any branch must meet the minimum flow rate of 8 cubic metres per hour.
NOZZLE CONFIGURATIONS
The Net ‘N’ Clean nozzles have a unique multi configuration system where each one can be set at up to 4 different orifice
sizes. As you increase the orifice size, you increase the flow ability of the system.
To alter the configuration of a nozzle,
Reminder: Nozzle combinations per branch must exceed minimum flow rate of 8 cubic metres per hour. No branch can
operate with a single nozzle, the minimum combination can be 2 x S3 or 1 x S2 and 1 x S4.