![Fluidmaster S2DBL Installation Instruction Download Page 3](http://html1.mh-extra.com/html/fluidmaster/s2dbl/s2dbl_installation-instruction_2308864003.webp)
3
1
2
Use Channel Locks® to loosen and
remove flush valve nut.
Cover the toilet seat with a towel. Place
the tank horizontally on top of the towel.
This will protect both surfaces.
(1) Remove flush valve. (2) Loosen and remove lever nut (lever nut is reverse threaded).
(3) Remove old gasket.
NOTE: SAVE the existing parts until installation is complete.
Measure and record distance of old flush
valve from bottom of tank to top of the
overflow tube.
Use screw driver to loosen nuts in
tank. Use crescent wrench to loosen if
the nut is too tight. Remove tank from
bowl.
www.fluidmaster.com
3
Measure flush valve
1.6 Remove lock nuts
1.3
1.4 Remove tank
Place tank on seat
1.5
1.7 Remove old parts