7
STEP 5:
REMOVE AND REPLACE OLD LEVER
6
STEP 4:
INSTALL NEW SEAL
INSERT
A:
REPLACE RED SEAL
Be sure seal is
positioned in the
very
top groove at bottom of
flush valve tower.
Proceed to
Step 4B only if keeping your original lever.
If replacing lever, proceed to
Step 5A.
B:
INSTALL NEW LEVER
Slide lever through tank hole.
Slip locknut over lever arm
(flat side of nut facing handle).
Loosely hand-tighten locknut
clockwise (reverse thread).
A:
REMOVE LEVER
Unscrew tank lever nut by
twisting
counterclockwise,
remove nut and pull lever
from tank.
C:
ATTACH LEVER TO
FLUSH VALVE TUBE
Thread lever arm through flush
valve loop while replacing
tube onto tower. If reattaching
original chain, clip to lever hole.
Hand-tighten locknut fully. Do
not overtighten.
Pliers
(Optional)
NOTE: May require pliers
if stuck.
B:
ATTACH LEVER TO
FLUSH VALVE TUBE
Thread lever through flush
valve loop while replacing
tube onto tower.
Hand-tighten locknut.
Do not overtighten. If
reattaching original chain,
clip to lever hole. Proceed
to
Step 5D.
D:
REPLACE FLUSH
VALVE STOP CAP
Twist
stop cap (a) right
(clockwise) to secure.
Hand-tighten only.
Do not
overtighten.
a