DO NOT USE IN-CISTERN DROP-IN TOILET BOWL
CLEANERS CONTAINING BLEACH OR CHLORINE.
Use of such products will: (1) RESULT IN
DAMAGE to Cistern components and MAY CAUSE
FLOODING and PROPERTY DAMAGE and (2) VOID
FLUIDMASTER WARRANTY.
DO NOT overtighten nuts or cistern/bowl may
crack. Always use quality Fluidmaster parts when
installing or repairing. Fluidmaster will not be
responsible or liable for use of non-Fluidmaster
parts during installation or repair.
WARNING
WARRANTY - Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure and for
compensation for any other reasonably foreseeable loss or damage. You are also entitled to
have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
To present claims under this warrantly, please contact your place of purchase or
contact Fluidmaster Holding Australia Pty Ltd.
Warranty period is two years from date of purchase. Warranty excludes incorrect
installation. Warranty on Replaceable Silicone Outlet Washer is subject to water
conditions and fair wear and tear.
IN NEW ZEALAND Call 09 415 5585
Replacement Silicone
Outlet Washer
Part # 56-01
Wedge Flush Pipe
Washer
Part # 56-02
Flush Pipe
Locking Collar
Part # 56-03
Tank to Bowl Gasket (Foam)
For Close Coupled Only
Part # 56-04
Tank to Bowl Gasket (Rubber)
For Close Coupled Only
Part # 6100
OTHER REPLACEMENT PARTS AVAILABLE SEPARATELY
Maximum water level within the cistern tank must be no higher than 20mm below the top of the outlet valve overflow tube. The overflow tube may be raised or lowered
depending on the maximum required level of water for a full flush, however the overflow height must always be 25mm below the critical level (CL) marked on the Inlet
Valve to ensure an Air Gap.
Note: Position cable opposite to inlet fill valve and ensure cable does not interfere with any moving parts within
toilet cistern.
TURN ON WATER SUPPLY.
Fill tank with additional 3 litres (6 Litre total),
for 6/3L Flush or Fill Tank with additional 1
1/2
litres (4.5 Litre total) for 4.5/3L Flush then mark
the top of Water Level. This is your Full Flush,
adjust the Full Flush Tab to set this volume.
(For older 9/4.5L flush toilet cisterns, use 4.5L
to set half flush mark and add 4.5L on top of
half flush volume to achieve 9L full flush volume
mark)
To establish water levels, pour in 3 litres of
water, then press full flush. This will establish
the residual water level mark, then add 3 litres
on top of the residual water and mark the top of
the water level. This is your 3 litre volume.
Adjust half flush tab on the side to flush 3 litres.
Please retain instructions for future reference.
Fluidmaster 580AU Cable Dual Flush Valve Suits Flush Volumes:
4.5 Litre / 3 Litre
6 Litre / 3 Litre
9 Litre / 4.5 Litre
FLUIDMASTER
®
580AU CABLE DUAL FLUSH VALVE
INSTALLATION INSTRUCTIONS FOR TOILET CISTERN
Close Coupled Cisterns
:
Place rubber gasket on pan
hole and centre the tank onto
the washer. Where required,
place bolts downwards in bolt holes and tighten.
PART# 25-1329 Grev 4 09/17
IMPORTANT: DO NOT USE PLUMBER´S PUTTY TO SEAL THIS CABLE DUAL FLUSH VALVE
7B
NB: Shank length may be cut to
suit Close Coupled Cisterns
8
9
10
Fluidmaster Holding Australia Pty Ltd
5B/100 New Street
Ringwood, Victoria 3134
Australia
Phone: +61 (03) 8870 2555
Toll Free: 1 800 931 166
Email: [email protected]
Website: www.Fluidmaster.com.au
File Name:
25-1329_Grev4_580AU_Instructions_092817
Printing & Finishing: 4/C Offset
Colors:
C
M
Y
K
DIE
PMS Colors: