Please  read  the  following  instructions  before  conducting  a 
new installation.

 

The pumps of the DGD series are direct-drive 

pumps,  while  those  of  the  DGM  series  are  magnetic-drive 
pumps.  The  DGD  and  DGM  units  must  be  handled  only  by 
specialised personnel who have the basic technical knowledge 
related to hydraulic and electromechanical installations.

WARNINGS

The  gear  pumps  part  of  the  DGD  and  DGM  series  are 
normally  assembled  with  non-protected  motors  in  case 
of  “locked  rotor”.  This  is  why  we  recommend  inserting  a 
fuse  and  adequately  sized  components  in  the  power  supply 
circuit  to  withstand  this  condition.  Inadequate  circuits  and/or 
components may overheat, causing damage and/or a fire. 
Before  connecting  the  motor  is  necessary  to  check  the 
polarity is correct. During installation be careful not to reverse 
the  polarity,  in  which  case  the  pump  would  rotate  in  the 
opposite  direction  and  for  some  motors  this  could  cause 
permanent damage to the unit itself. 

For  the  DGM  version,  the  flange  must  be 
handled carefully.
Do not handle it with tongs or vice that could 
lead to a misalignment of the magnets and a 
decline  in  the  pump’s  performance.  In  case 
of  continuous  operation,  the  unit  must  be 
installed in a ventilated 

space to dissipate the heat generated by the motor.
In  order  to  avoid  noise  and  vibration  of  mechanical  parts, 
we  recommend  installing  the  unit  with  rubber  anti-vibration 
mounts.  Take  special  care  when  connecting  the  pump  to 
the fittings in order to avoid potential leaks. The pipe holders 
integrated  in  the  DGD  and  DGM  pumps  are  designed  to  be 
coupled with silicone pipes (60ShA) with an internal diameter 
measuring 6 mm and 1.5 mm thick. 
Other  types  of  pipe  could  damage  the  pump.  The  unit’s 
pipe  holders  are  not  designed  to  withstand  any  mechanical 
load. We recommend fastening at least the delivery pipe with 
a  plastic  strap.  We  recommend  removing  the  two  plastic 
plugs  located  in  the  pump’s  intake  and  delivery  ducts  just 
before mounting the fittings and pipes to prevent solid foreign 
objects  from  entering  inside,  as  they  could  damage  the 
internal components of the pump.
Do not use liquid sealant, as drops could fall in the ducts and 
cause the pump to block.
For use in the food industry, the pumps (even if NSF-certified) 
must  first  be  sterilised  by  circulating  water  inside  them  at 
a  temperature  of  80  °C/176  F  for  at  least  20  minutes.  The 
water  used  for  this  operation  must  not  be  reused  during  the 
sterilisation or thereafter, but must be flushed away. If the unit 
is replaced, it is necessary to ensure that the model matches 
the  one  being  replaced.  Change  the  unit  with  one  with  a 
different flow rate could damage the system. The circuit must 
be thoroughly cleaned and rinsed before starting up the unit.

INSTALLATION

MANUAL - DGD/DGM  en. - 06/13 Ed.

Fluid-o-Tech reserves the right to alter the specifications indicated in this catalogue at any time and without prior notice.

GENERAL SAFETY ADVICE

1

  The  DGD  and  DGM  pumps  are  often  powered  by  DC  motors 

with  brushes,  a  known  source  of  ignition.  Do  not  use  these 
motors in potentially explosive atmospheres. 

After prolonged use or applications with hot fluids, the surfaces 
of the pump and the motor could be hot and potentially cause 
injury  to  skin  or  burns.  After  disconnecting  the  power  supply, 
wait for the pump to cool down before touching it. 

Do  not  place  the  pump  near  materials  with  low  auto-ignition 
temperature/flammable  materials.  The  outer  surfaces  of  the 
unit can reach high temperatures. Install the pump in a dry area 
protected from dust, splashes and condensation. 

4.

Often motors are cooled by natural convection. We recommend

installing  the  unit  in  areas  where  maximum  and  adequate 
ventilation  is  ensured.  As  an  indication,  the  minimum  distance 
from the walls around the unit should be at least 50 mm. Do not 
wrap the unit with insulation material and do not install it near hot 
surfaces. Do not use the pump in environments or with fluids at 
temperatures higher than those reported in the catalogue.

5

  Check the compatibility with the fluid used beforehand. Do not 

use or allow the pump to come in contact with chemicals that 
could damage the unit.

6

  An  inadequate  circuit  could  cause  excessive  pressure  or 

overheating. Make sure the unit is used in accordance with to 
the curves in the catalogue.
Install the hydraulic circuit with adequate safety margins, both in 
terms of pressure and temperature.