Fuel Meter 
 

1 | 

P a g e                                                

flowtech-instruments.com

 

 

 

 

1.

 

Introduction 

OMFF/OFS Series aluminium oval gear flow meter has the ability to handle a wide range of fluid viscosities with 
exceptional levels of repeatability and durability, applying in the petroleum, chemical, food industry, etc. 

It is also applicable in Diesel, Kerosene and Petrol fluid usage industries 

Flowtech provides Fuel Flow Meter from FMIPL-OFMM-025 to 50 Positive Displacement Fuel Meter. The Diesel 
Flow Meter FMIPL-OFMM-025 to 50 has also incorporated the oval rotor principal into its design.  
 
This has proven to be a highly reliable and highly accurate method of measuring flow, providing exceptional 
repeatability and high accuracy. The low pressure drop through the meter makes the meter ideally suited for use 
in gravity applications or with the Diesel Flow Meter & Digital Diesel Flow Meter range of electric fuel pumps. 

 

2.

 

Technical Specification 

 

Model 

OFMM-025 

OFS-025 

OFMM-040 

OFS-040 

OFMM-050 

OFS-050 

Size 

25MM 

40MM 

50MM 

Min Flow (LPM) 

12 L/Min 

25 L/Min 

30 L/Min 

Max Flow (LPM) 

120 L/Min 

250 L/Min 

300 L/Min 

Accuracy 

 +/- 0.5% 

 +/- 0.5% 

+/- 0.5%  

Repeatability 

0.03% 

0.03% 

0.03% 

Max Viscosity 

1000 CPS 

1000 CPS 

1000 CPS 

Best Working Pressure 

0.3 Mpa 

0.3 Mpa 

0.3 Mpa 

 

3.

 

Operating Principle 

The oval gear flow meter comprises oval-shaped, geared rotors which 
rotate within a housing of specified geometry as shown in the diagram 
below. One of the rotors is fitted with a gearing pinion which (through 
a  secondary  gearing  set)  transfers  the  rotation  of  the  rotor  to  the 

Mechanical Register. 

Fluid differential pressure

 causes the intermeshing gears to rotate, trapping a 'pocket' of 

fluid between the gear and the outer housing and subsequently emptying the fluid pocket into the downstream 
flow. 

The measurement part of oval gear flow meter is 
posed  by  two  elliptical  gears  mesh  with  each 
other and its shell (measuring room).  

The flow meter works by two elliptical gears to 
mesh with each other, its working process are as 
follows: P1 in the figure shows the pressure of 

Summary of Contents for OFMM-025

Page 1: ...Oval Gear Flow Meter Flowtech Measuring Instruments Pvt Ltd Email info flowtech instruments com flowtech01 gmail com Website flowtech instruments com Mobile Number 8469769988 9428876496 8160255957 ...

Page 2: ...ification Model OFMM 025 OFS 025 OFMM 040 OFS 040 OFMM 050 OFS 050 Size 25MM 40MM 50MM Min Flow LPM 12 L Min 25 L Min 30 L Min Max Flow LPM 120 L Min 250 L Min 300 L Min Accuracy 0 5 0 5 0 5 Repeatability 0 03 0 03 0 03 Max Viscosity 1000 CPS 1000 CPS 1000 CPS Best Working Pressure 0 3 Mpa 0 3 Mpa 0 3 Mpa 3 Operating Principle The oval gear flow meter comprises oval shaped geared rotors which rota...

Page 3: ... of the pump negative suction pressure the liquid at the outflow of the pump shaft also causes the flow meter error increases the flange of the pump suction side should be designed to prevent leakage otherwise it can also cause the error increases to the flow meter 5 A filter should be installed at the front of the flow meter to prevent greater than 0 2mm tiny particles blocking the flow meter and...

Page 4: ... of the oval gear rotation 1 Installation is jammed when the gear impurities fall into the flow meter Reinstall removed after cleaning Installation follows the mark on the oval gear An annotated mark installed oval gear 2 The measured liquid impure filter clogging impurities Clearing filter to remove impurities 3 The measured pressure of the liquid is too small Increase the pressure Oval gear rota...

Page 5: ...s at 90 degrees to each other and check their operation by turning either of the rotors If the rotors are not in mesh correctly or do not move freely remove one of the rotors and replace correctly at 90 degrees to the other rotor 3 Re check the operation of the rotors 4 Inspect the gears in the meter cap for wear Replace if required refer to exploded diagram 5 Replace the o ring into groove in the...