10.4 Push the stationary face radially into the gland and then down as
the lock pin slips into the lock pin slot. The stationary face should
sit flush with the spring holder.
10.5 Repeat this procedure for the other gland half.
10.6 Lubricate the exposed surfaces of the split joint gaskets with silicon
grease.
10.7 Loosely cap screw the halves together.
10.8 Align the stationary faces and wipe them clean with alcohol.
Caution:
Consult material safety data sheets for proper handling of alcohol.
11 Centering Device Installation
11.1 Place the gland assembly on
the table face down.
11.2 Set one centering device on
the gland and press the
centering device fastener
through the centering device
and into the locating hole in
the gland. The locating holes
are located 45 degrees from
the split joints and are even
with the bolt slots.
See Figure 30.
Note: Newer PSS II seal designs
use a one piece centering device
that can be pressed into place
without a separate fastener.
11.3 Repeat this procedure for all
four centering devices.
See Figure 31.
Figure 31
Figure 30