11
Figure 25
Figure 26
8 Gland Split Joint Gasket Installation
Figure 27
2 Dots Here
8.1 Wipe the gland split joint gasket
groove clean with alcohol.
Caution:
Consult material safety data sheets
for proper handling of alcohol.
8.2 Put one dot of adhesive in the
groove as shown in Figure 25.
One Dot Here
8.3 Place the split joint gasket in the groove. Make sure it is flush with
the back of the gland gasket, the back and top of the seat gasket,
and the top of the split joint gasket groove. Hold it in place for
10 seconds. See Figure 26.
8.4 Apply two more dots of glue as
shown in Figure 27.
8.5 Align the split joint gasket with
the seat gasket and gland
gasket as shown in Figure 26.
Hold it in place for 10 seconds.
8.6 Repeat this procedure for the
other gland half.
Flush
Flush
Flush