Limitorque L120-85 Installation, Operation and Maintenance FCD LMENIM1202-03-A4 – 06/15
10
4.1.1 Torque Only Applications (Drive 1) (Refer to Figure 27)
Remove the Torque Nut Retaining Ring (piece 98) and Torque Drive Nut (piece 95) from actuator.
Figure 2: L120-85 Torque Drive Nut and Retaining Ring Details
#95 Torque
Drive Nut
#98 Torque Nut
Retaining Ring
A) If Torque Drive Nut has been bored and keywayed by supplier, verify dimensions of keyway for proper compatibility with the valve stem.
B) If Torque Drive Nut has not been bored and keywayed by supplier, it is provided solid (blank) to allow customer to custom bore and key
up to the maximum permissible sizes as listed:
Table 2: Torque Drive Nut: Maximum Allowable Bore and Key Sizes
Key Type
Maximum Bore in. (mm)
Maximum Key in. (mm)
Rectangle
2.750 (69.85)
.625 x .4375 (20 x 12)
Square
2.625 (66.67)
.625 x .625 (20 x 20)
4.1.2 Torque and Thrust Applications (Drive 2) (Refer to Figure 28)
Remove Socket Head Cap Screw (piece 110) and Lockwasher (piece 111) that holds the Thrust Base Housing Assembly to the actuator
Housing (piece 1).
Figure 3: Thrust Base removal from an L120-85
#111 Lockwasher
#110 Socket Head
Cap Screw
#100 Thrust Base
Housing
#1 Housing
#101 Thrust Base
Drive Sleeve