![Flowserve FlowAct 1502 User Instructions Download Page 51](http://html1.mh-extra.com/html/flowserve/flowact-1502/flowact-1502_user-instructions_2308443051.webp)
FlowAct Diaphragm Linear Actuator FCD VLENIMFACTA4 10/16
51
flowserve.com
22. Connect the actuator with the air supply, perform 3 full
strokes and check the free movement.
NOTICE
The stem extension must be able to
move freely without hitting in the end
positions.
23. Log the maintenance interval and the work performed.
24. The actuator subassembly is ready to be mounted on
the valve and the accessories attached.
Item #
Part
WW
EU
221
6.120
Stem Extension
256
5.11
Lock Nut
350
6.122
Stem End Stop
352
6.121
Cover Tube
353
6.124
Lock Nut
370
6.96
Hex Socket Set Screw
372
6.42
Central Handwheel (Unit)
405
6.123
Slotted Set Screw (4x)
352
256
221
405
350
353
370
Actuator
372
405
Table 32: Handwheel “central“ parts
Figure 29: Handwheel “central“ parts