background image

3

Flow Control

Kämmer Control Valves

®

4  

QUIcK cHecK:

 

Before operating, check the valve as follows:

4.  

Open and close the valve, and observe the movement 

of the actuator stem. The movement must be smooth 

and linear.

4.2  

Check for maximum stroke through change of signal 

(for  pneumatic  positioners,  0.2  -  .0  bar  or  corre-

sponding split-range values; for IP positioners, 4-20 

or 0-20 mA).

4.3  

Check all air connections for leaks.

4.4  

Tighten packing nut (see table ).

 

nOte: 

An excessively tightened gland nut can cause 

excessive packing wear and can hinder the free move-

ment of the plug stem.

4.5  

Check fail-safe position. To do this, close supply pres-

sure and observe whether the valve opens or closes 

as defined.

4.6  

After use at fluctuating temperatures, re-tighten all bolt 

connections and check for leaks.

5  

MaIntenance 

 

Check valves for correct functioning at regular  

intervals (at least once every 6 months) as follows. 

This  check  can  be  made  when  installed  and  in 

many   cases  without  interrupting  production. 

If  internal  defects  are  suspected,  see  section 

„Disassembly and Assembly of Valve“. 

5.  

Examine gaskets for leaks and if necessary re-tighten 

bolts (see Fig. ).

5.2  

Check bellows gasket and test connection  - if present 

- for external leaks.

5.3  

Check valve for damage caused by corrosive residues 

or corrosive vapours.

5.4 

Clean valves and repaint as necessary.

 

Warning:

 

To prevent a buildup of electrostatic charge 

clean the actuator/valve with a damp cloth only.

5.5  

Check gland nut for correct torque (see table ).

 

nOte: 

An excessively tightened gland nut can cause 

excessive packing wear and can hinder the free move-

ment of the plug stem.

5.6  

If possible, open and close valve and check for maxi-

mum stroke and smooth movement of the plug stem. 

Irregular  movement  of  the  plug  stem  may  indicate 

internal defects.

 

nOte

: With graphite packing, irregular movement of 

the plug stem is normal.

 

WarnIng: 

Keep hands, hair, clothing, etc. away from 

all moving parts. Failure to do so can lead to serious 

injury.

5.7  

Check all accessories for firm seating.

5.8  

If possible, close supply pressure and check the fail-

safe position. 

5.0   Check stem boot for wear.

5.   Check actuator for leaks. To do this, spray housing, 

air connections and plug stem guide with leak spray 

and check for any bubble formation.

5.2   Clean plug stem.

5.3   Check air filter, if present, and if necessary replace 

insert.

 

nOte: 

For further information regarding service and 

maintenance please contact your nearest FLOWSERVE 

office.

 

danger:

   

On  actuators  with  aluminium  cases  the 

actuator springs must be renewed with original spare 

parts every 10 years or after 50.000 operating hours 

which ever occurs first.

  

table 1

STOP!

STOP!

   

     

                   torque nm

  thread 

PtFe 

  grafoil

  M20 x ,5 

3.5 

 

6.0

  M30 x ,5 

7.0 

 

7.5

  M38 x ,5 

.5 

 

20.5

  M45 x ,5 

27.0 

 

48.0

Summary of Contents for 035 000 Series

Page 1: ...ith regard to transport assembly operation and maintenance and with regard to technical documentation e g in the operating instruction product documentation or on the product itself is essential in or...

Page 2: ...Fire protection for K mmer products must be provided by the end user 1 7 Service repair To avoid possible injury to personnel or damage to products safety terms must be strictly adhered to Modifying t...

Page 3: ...or corrosive vapours 5 4 Clean valves and repaint as necessary Warning To prevent a buildup of electrostatic charge clean the actuator valve with a damp cloth only 5 5 Check gland nut for correct tor...

Page 4: ...upling Coupling screws Coupling insert Locknut Yoke plate Yoke nuts Actuator series 2 Fig 1a Zero adjustment locknut Actuator stem Travel indicator Yoke plate Yoke nuts Cap Locknuts Gland nut Clamping...

Page 5: ...using and the actuator is aligned forward If the actuator is fitted with a coupling refer to the procedure described in the maintenance instructions for the I P actuator NOTE Ensure that the plug asse...

Page 6: ...ves Packing kit see spare parts list Trim see spare parts list Locknut Gland nut Packing follower Clamping nut Nut Bonnet Bolt stud depends on design Gasket Body Bore for adjustable face pin tool Fig...

Page 7: ...sembled lapping is not required NOTE When re machining the plug protect plug stem from damage The seat surface must be concentric to the plug stem When re finishing the seat the seat surface must be c...

Page 8: ...rmano Milano E 28002 Madrid Porto 4100 082 58933 Link ping sterg tland Italy Spain Portugal Sweden Telephone 39 0 2663251 Telephone 34 9 15 152 032 Telephone 351 22 619 8770 Telephone 46 13 316100 Fac...