FlowLine Smart Trak AU18-4343 Owner'S Manual Download Page 3

MN301420 rev A 

 3 

|

 

Components

 

Step Two 

  

 

ONE SENSOR CONFIGURATION:

 

(AU18-434_, AV16-434_ or AZ18-434_)

 

TWO SENSORS CONFIGURATION:

 

(AU28-434_, AV26-434_ or AZ28-434_)

 

 

 

Ultrasonic 

AU18-4343 

1 x LU10-1305 
1 x LM10-1_01 
1 x LM30-1001 
1 x LC05-1001 

Buoyancy 

AV16-4343 

1 x LV10-1301 
1 x LM10-1_01 
1 x LM30-1001 
1 x LC05-1001 

Vibration

AZ18-4343 

1 x LZ12-1405 
1 x LM10-1_01 
1 x LM30-1001 
1 x LC05-1001 

Ultrasonic

AU28-4343 

2 x LU10-1305 
1 x LM10-1_01 
2 x LM30-1001 
1 x LC05-1001

 

Buoyancy 

AV26-4343 

2 x LV10-1301 
1 x LM10-1_01 
2 x LM30-1001 
1 x LC05-1001

 

Vibration

AZ28-4343 

2 x LZ12-1405 
1 x LM10-1_01 
2 x LM30-1001 
1 x LC05-100

 

AU18-4347 

1 x LU10-1325 
1 x LM10-1_61 
1 x LM30-1051 
1 x LC05-1051 

AV16-4347 

1 x LV10-1351 
1 x LM10-1_61 
1 x LM30-1051 
1 x LC05-1051 

AZ18-4347

1 x LZ12-1405 
1 x LM10-1_61 
1 x LM30-1001 
1 x LC05-1051 

AU28-4347

2 x LU10-1325 
1 x LM10-1_61 
2 x LM30-1051 
1 x LC05-1051

 

AV26-4347 

2 x LV10-1351 
1 x LM10-1_61 
2 x LM30-1051 
1 x LC05-1051

 

AZ28-4347

2 x LZ12-1405 
1 x LM10-1_61 
2 x LM30-1001 
1 x LC05-1051

 

 

THREE SENSORS CONFIGURATION:

 

(AU18-434_, AV16-434_ or AZ18-434_)

 

FOUR SENSORS CONFIGURATION:

 

(AU28-434_, AV26-434_ or AZ28-434_)

 

 

 

Ultrasonic 

AU38-4343 

3 x LU10-1305 
1 x LM10-1_01 
3 x LM30-1001 
1 x LC05-1001 

Buoyancy 

AV36-4343 

3 x LV10-1301 
1 x LM10-1_01 
3 x LM30-1001 
1 x LC05-1001 
 

Vibration

AZ38-4343 

3 x LZ12-1405 
1 x LM10-1_01 
3 x LM30-1001 
1 x LC05-1001 

Ultrasonic

AU48-4343 

4 x LU10-1305 
1 x LM10-1_01 
4 x LM30-1001 
1 x LC05-1001

 

 

Buoyancy 

AV46-4343 

4 x LV10-1301 
1 x LM10-1_01 
4 x LM30-1001 
1 x LC05-1001 

 

Vibration

AV48-4343 

4 x LZ12-1405 
1 x LM10-1_01 
4 x LM30-1001 
1 x LC05-1001 

 

AU38-4347 

3 x LU10-1325 
1 x LM10-1_61 
3 x LM30-1051 
1 x LC05-1051 

AV36-4347 

3 x LV10-1351 
1 x LM10-1_61 
3 x LM30-1051 
1 x LC05-1051 

AZ38-4347

3 x LZ12-1405 
1 x LM10-1_61 
3 x LM30-1001 
1 x LC05-1051 

AU48-4347

4 x LU10-1325 
1 x LM10-1_61 
4 x LM30-1051 
1 x LC05-1051

 

AV46-4347 

4 x LV10-1351 
1 x LM10-1_61 
4 x LM30-1051 
1 x LC05-1051

 

AZ48-4347

4 x LZ12-1405 
1 x LM10-1_61 
4 x LM30-1001 
1 x LC05-1051 

 

COMPONENT LIST:

 

 

 

Smart Trak Fitting 

P/N: LM10-1_01 or LM10-1_61

 

 

Compact Junction Box 

P/N: LC05-1001 or LC05-1051

 

Switch Car Kit 

P/N: LM30-1001 or LM30-1051

 

Switch-Tek Level Switch 

P/N: LU10-1305. LU10-1325, 

LV10-1301, LV10-1351 

or LZ12-1405

 

Summary of Contents for Smart Trak AU18-4343

Page 1: ...00 Humbolt Street Los Alamitos CA 90720 p 562 598 3015 f 562 431 8507 w flowline com MN301420 Rev A Smart Trak w Compact Junction Box AU18 AU28 AU38 AU48 AV16 AV26 AV36 AV46 AZ18 AZ28 AZ38 AZ48 Series...

Page 2: ...DC 0 5A Cable type 4 conductor sensor 22AWG shielded Contact output Selectable NO NC Classification Intrinsically safe CE compliance EN 50082 2 immunity EN 55011 emission EN 61010 1 safety VIBRATION S...

Page 3: ...THREE SENSORS CONFIGURATION AU18 434_ AV16 434_ or AZ18 434_ FOUR SENSORS CONFIGURATION AU28 434_ AV26 434_ or AZ28 434_ Ultrasonic AU38 4343 3 x LU10 1305 1 x LM10 1_01 3 x LM30 1001 1 x LC05 1001 B...

Page 4: ...silicon gel for lubrication Wire gasket o Santoprene w silicon gel for lubrication Seal plug Make sure that the application liquids are compatible with the materials that will be wetted To determine...

Page 5: ...The track may be cut to length if desired Four separate grooves run the length of the track one on each side of the square These grooves hold the sensor cars that attach to Flowline sensors and also...

Page 6: ...ogy along the entire length of track Smart Trak may be installed thru the top wall of any tank or flange using a standard 2 NPT tank adapter or blind flange If tank top is not available Flowline s sid...

Page 7: ...el switches will be staggered through the fitting for installation A key feature of Smart Trak is the adjustability of the level switches When two level switches are placed close together one of the s...

Page 8: ...y either connecting the Green to VDC power or White to VDC power see illustration below SWITCHING A NORMALLY CLOSED DC LOAD The Black wire connects to Positive of the power supply and the Red wire con...

Page 9: ...mally open state Normally open is defined as the switch being open when the float is dry and closed when the float becomes submersed This operation is typical for indicating a high level Normally Clos...

Page 10: ...RAWING SIDE VIEW Inventory One Smart Trak kit LM10 1__1 includes the following parts 1 Seal Plug 1 Top compression fitting 1 Wire gasket 1 Thrust Plate 1 Locking pin 1 2 NPT fitting 1 Track 1 End cap...

Page 11: ...between to provide tension for the push and turn connection SWITCH CAR KIT ASSEMBLY DRAWING SIDE VIEW INVENTORY One switch car kit LM30 10_1 consists of the following parts 1 Locking bolt 1 Locking N...

Page 12: ...atible solvents which may damage the sensor s PP or Ryton plastic body 4 Sensor Installation Follow the appropriate steps of installation as outlined in the installation section of this manual TESTING...

Page 13: ...t is switching between dry open and wet closed Test requires Red wired to Positive and Black wired to Negative on a 12 to 36 VDC power supply Check for continuity across Green and White open for dry a...

Page 14: ...ocedures outlined above 2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service person...