background image

14

 

of

 

14

 

MN301030

 

Rev

 

B

 

Warranty,

 

Returns

 

&

 

Limitations

  

Step

 

Eleven

 

 

Warranty

 

Flowline

 

warrants

 

to

 

the

 

original

 

purchaser

 

of

 

its

 

products

 

that

 

such

 

products

 

will

 

be

 

free

 

from

 

defects

 

in

 

material

 

and

 

workmanship

 

under

 

normal

 

use

 

and

 

service

 

in

 

accordance

 

with

 

instructions

 

furnished

 

by

 

Flowline

 

for

 

a

 

period

 

of

 

two

 

years

 

from

 

the

 

date

 

of

 

manufacture

 

of

 

such

 

products.

 

Flowline's

 

obligation

 

under

 

this

 

warranty

 

is

 

solely

 

and

 

exclusively

 

limited

 

to

 

the

 

repair

 

or

 

replacement,

 

at

 

Flowline's

 

option,

 

of

 

the

 

products

 

or

 

components,

 

which

 

Flowline's

 

examination

 

determines

 

to

 

its

 

satisfaction

 

to

 

be

 

defective

 

in

 

material

 

or

 

workmanship

 

within

 

the

 

warranty

 

period.

 

Flowline

 

must

 

be

 

notified

 

pursuant

 

to

 

the

 

instructions

 

below

 

of

 

any

 

claim

 

under

 

this

 

warranty

 

within

 

thirty

 

(30)

 

days

 

of

 

any

 

claimed

 

lack

 

of

 

conformity

 

of

 

the

 

product.

 

Any

 

product

 

repaired

 

under

 

this

 

warranty

 

will

 

be

 

warranted

 

only

 

for

 

the

 

remainder

 

of

 

the

 

original

 

warranty

 

period.

 

Any

 

product

 

provided

 

as

 

a

 

replacement

 

under

 

this

 

warranty

 

will

 

be

 

warranted

 

for

 

the

 

full

 

two

 

years

 

from

 

the

 

date

 

of

 

manufacture.

 

Returns

 

Products

 

cannot

 

be

 

returned

 

to

 

Flowline

 

without

 

Flowline's

 

prior

 

authorization.

 

To

 

return

 

a

 

product

 

that

 

is

 

thought

 

to

 

be

 

defective,

 

go

 

to

 

www.flowline.com,

 

and

 

submit

 

a

 

customer

 

return

 

(MRA)

 

request

 

form

 

and

 

follow

 

the

 

instructions

 

therein.

 

All

 

warranty

 

and

 

non

warranty

 

product

 

returns

 

to

 

Flowline

 

must

 

be

 

shipped

 

prepaid

 

and

 

insured.

 

Flowline

 

will

 

not

 

be

 

responsible

 

for

 

any

 

products

 

lost

 

or

 

damaged

 

in

 

shipment.

 

Limitations

 

This

 

warranty

 

does

 

not

 

apply

 

to

 

products

 

which:

 

1)

 

are

 

beyond

 

the

 

warranty

 

period

 

or

 

are

 

products

 

for

 

which

 

the

 

original

 

purchaser

 

does

 

not

 

follow

 

the

 

warranty

 

procedures

 

outlined

 

above;

 

2)

 

have

 

been

 

subjected

 

to

 

electrical,

 

mechanical

 

or

 

chemical

 

damage

 

due

 

to

 

improper,

 

accidental

 

or

 

negligent

 

use;

 

3)

 

have

 

been

 

modified

 

or

 

altered;

  

4)

 

anyone

 

other

 

than

 

service

 

personnel

 

authorized

 

by

 

Flowline

 

have

 

attempted

 

to

 

repair;

 

5)

 

have

 

been

 

involved

 

in

 

accidents

 

or

 

natural

 

disasters;

 

or

 

6)

 

are

 

damaged

 

during

 

return

 

shipment

 

to

 

Flowline.

 

Flowline

 

reserves

 

the

 

right

 

to

 

unilaterally

 

waive

 

this

 

warranty

 

and

 

dispose

 

of

 

any

 

product

 

returned

 

to

 

Flowline

 

where:

 

1)

 

there

 

is

 

evidence

 

of

 

a

 

potentially

 

hazardous

 

material

 

present

 

with

 

the

 

product;

 

or

 

2)

 

the

 

product

 

has

 

remained

 

unclaimed

 

at

 

Flowline

 

for

 

more

 

than

 

30

 

days

 

after

 

Flowline

 

has

 

dutifully

 

requested

 

disposition.

 

This

 

warranty

 

contains

 

the

 

sole

 

express

 

warranty

 

made

 

by

 

Flowline

 

in

 

connection

 

with

 

its

 

products.

 

ALL

 

IMPLIED

 

WARRANTIES,

 

INCLUDING

 

WITHOUT

 

LIMITATION,

 

THE

 

WARRANTIES

 

OF

 

MERCHANTABILITY

 

AND

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE,

 

ARE

 

EXPRESSLY

 

DISCLAIMED.

 

The

 

remedies

 

of

 

repair

 

or

 

replacement

 

as

 

stated

 

above

 

are

 

the

 

exclusive

 

remedies

 

for

 

the

 

breach

 

of

 

this

 

warranty.

 

IN

 

NO

 

EVENT

 

SHALL

 

FLOWLINE

 

BE

 

LIABLE

 

FOR

 

ANY

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES

 

OF

 

ANY

 

KIND

 

INCLUDING

 

PERSONAL

 

OR

 

REAL

 

PROPERTY

 

OR

 

FOR

 

INJURY

 

TO

 

ANY

 

PERSON.

 

THIS

 

WARRANTY

 

CONSTITUTES

 

THE

 

FINAL,

 

COMPLETE

 

AND

 

EXCLUSIVE

 

STATEMENT

 

OF

 

WARRANTY

 

TERMS

 

AND

 

NO

 

PERSON

 

IS

 

AUTHORIZED

 

TO

 

MAKE

 

ANY

 

OTHER

 

WARRANTIES

 

OR

 

REPRESENTATIONS

 

ON

 

BEHALF

 

OF

 

FLOWLINE.

 

This

 

warranty

 

will

 

be

 

interpreted

 

pursuant

 

to

 

the

 

laws

 

of

 

the

 

State

 

of

 

California.

 

If

 

any

 

portion

 

of

 

this

 

warranty

 

is

 

held

 

to

 

be

 

invalid

 

or

 

unenforceable

 

for

 

any

 

reason,

 

such

 

finding

 

will

 

not

 

invalidate

 

any

 

other

 

provision

 

of

 

this

 

warranty.

 

For

 

complete

 

product

 

documentation,

 

video

 

training,

 

and

 

technical

 

support,

 

go

 

to

 

www.flowline.com.

 

For

 

phone

 

support,

 

call

 

562

598

3015

 

from

 

8am

 

to

 

5pm

 

PST,

 

Mon

 ‐ 

Fri.

 

(Please

 

make

 

sure

 

you

 

have

 

the

 

Part

 

and

 

Serial

 

number

 

available.)

 

 

Summary of Contents for DeltaSpan LD30 Series

Page 1: ...n General Purpose External Mount Pressure Level Transmitter LD30 Series Manual Cable Series LD30 S_01 Conduit Series LD30 S_11 Flowline Inc 10500 Humbolt Street Los Alamitos CA 90720 Tel 562 598 3015 Fax 562 431 8507 www flowline com ...

Page 2: ...upply voltage ratings Permanent damage not covered by warranty will result This device is not designed for 120 or 240 volt AC operation Use only on 13 to 30 VDC Table of Contents Specifications 3 Dimensions 4 Technology 4 Material Compatibility 4 Safety Precautions 5 Components 6 Getting Started 7 How to convert Pressure into Liquid Height 7 How does Specific Gravity affect pressure transmitters 8...

Page 3: ...psig maximum 150 psig over pressure S4_1 60 psig maximum 300 psig over pressure Power Requirement 13 to 30 VDC Output Signal 4 to 20 mA 2 wire Response Time 50 ms Max Loop Resistance 1300 Ohms 30 VDC Current consumption 38 mA maximum Electrical Connections S_01 Cable 9 length S_11 Conduit Housing with Terminal Block Process connection male NPT Enclosure rating NEMA 4X IP 66 Mounting Orientation Mo...

Page 4: ...ure of the gas is generated from the microprocessor Cable Series LD30 S_01 Conduit Series LD30 S_11 Material Compatibility The LD30 series is made of 316 Stainless Steel 316 SS 316L Stainless Steel 316L SS The Cable Version LD30 S_01 is provided with 3 0 91 m of cable The Conduit Version LD30 S_11 is provided with a junction box including a terminal strip and a NPT conduit The total length the sig...

Page 5: ...this product Use a proper sealant with all installations Always check for leaks prior to system start up Wiring and Electrical CAUTION A supply voltage of 13 to 30 VDC is used to power the LD30 series transmitter Electrical wiring of the sensor should be performed in accordance with all applicable national state and local codes Temperature and Pressure The LD30 series is designed for use in applic...

Page 6: ...ow DeltaSpan General Purpose External Mount Pressure Level Transmitter Part Number Maximum Pressure Range in Water Column Interface Connection LD30 S001 LD30 S011 05 psi 11 54 ft wc 3 52 m wc 9 2 7 m Cable Terminal Block in Housing LD30 S201 LD30 S211 15 psi 34 63 ft wc 10 56 m wc 9 2 7 m Cable Terminal Block in Housing LD30 S401 LD30 S411 30 psi 69 30 ft wc 21 12 m wc 9 2 7 m Cable Terminal Block...

Page 7: ...installation method where the unit can be removed without having to remove the fluid from the vessel The use of valves between the transmitter and the vessel can allow transmitter removal without draining the fluid How to convert Pressure into Liquid Height Pressure transmitters are all defined by the pressure range and not by Liquid Height To convert pressure to Liquid Height use the following ra...

Page 8: ...psi x 2 31 psi 0 9 38 5 Note The above formula will always provide the Maximum Liquid Height for any pressure transmitter Example Compare the Maximum Liquid Height of a liquid with a SG 0 9 to one with a SG 1 0 SG 0 9 a 15 psi transmitter will have a Maximum Liquid Height 38 5 11 73 m SG 1 0 a 15 psi transmitter will have a Maximum Liquid Height 34 65 10 56 m A change in SG of 0 1 will increase th...

Page 9: ...1 Measure the Height Full Tank in feet or meters 2 Determine the SG for the liquid if the customer does not know check the MSDS sheet 3 Use the formula above to calculate the Pressure Full a Example A 16 tank with a liquid media SG of 0 9 has a Pressure Full of 6 23 psi b 16 x 0 9 2 31 psi 6 23 psi 4 Select a pressure transmitter with a pressure greater than or equal to the Pressure Full a In the ...

Page 10: ...e current when the tank is full To do this use the following formula Full Tank Height Maximum Liquid Height x 16 4 Current at Full Example A 16 foot tank with a SG 0 9 will have a maximum pressure of 6 23 psi A 15 psi sensor is selected for use The Maximum Liquid Height 15 psi x 2 31 psi 0 9 38 5 feet Using the above formula the Current at Full 40 feet 51 33 feet x 16 4 10 649 mA The Current at Fu...

Page 11: ...itter and receiver The range of appropriate receiver load resistance RL for the DC power supply voltage available is expressed by the formula RLmax Vsup 10V 20 mA DC Shielded cable is recommended for control loop wiring Use the Red wire 1 terminal as the and the Black wire 2 terminal as the Fig A Connections Cable Version LD30 S_01 Series Red Wire Black Wire Conduit Version LD30 S_11 Series Termin...

Page 12: ...l standard models are originally calibrated with the unit in a position with the pressure connection downward Although they can be used at other angles for best accuracy it is recommended that units be installed in the position calibrated at the factory 3 Pressure Connection Use a small amount of plumber s tape or other suitable sealants to prevent leaks Be sure the pressure passage inside the por...

Page 13: ...o not use harsh abrasives such as steel wool or sandpaper which might damage the surface of the sensor Do not use incompatible solvents which may damage the sensor s stainless steel body Take particular care to remove any scaling from the body and that there is no debris inside the inlet Transmitter installation Follow the appropriate steps of installation as outlined in the Installation section o...

Page 14: ...rocedures outlined above 2 have been subjected to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Flowline have attempted to repair 5 have been involved in accidents or natural disasters or 6 are damaged during return shipment to Flowline Flowline reserves the right to unilatera...

Reviews: