DataLoop™ LI23 Loop-Powered Process Meter
Instruction Manual
MN302100 Rev 3
17
Parameter
Action/Setting Description
RLY2
Start/stop relay 2 timer
START
Start the selected timer output
STOP
Stop the selected timer output
STR‐STP
Start or stop the selected timer
output
ALARM.FN
Set the function key or digital input
to acknowledge an alarm or ac-
cess set points
ACK
Acknowledge all active alarms
SETPOINT
Access all output set points
SETPT.OC1
Access open collector 1 set point
SETPT.OC2
Access open collector 2 set point
SETPT.R1
Access relay 1 set point
SETPT.R2
Access relay 2 set point
SWATCH.FN
Set the function key or digital input
to activate stopwatch
START
Start the stopwatch
STOP
Pause/Stop the stopwatch
STR‐STP
Start or stop the stopwatch
TARE.FN
Set the function key or digital input
to tare the display
TARE
Tare the display value
RST TARE
Reset the display value
HOLD FN
Set the function key or digital input
to hold an output
HOLD.OUT
Hold all outputs
HLD.UNHLD
Hold or un-hold all outputs
OC1+2
Hold/un-hold open collector out-
puts
RLY1+2
Hold/un-hold relay outputs
mAOUT
Hold/un-hold 4-20 mA output
HOLD
Hold selected output
HLD.UNHLD
Hold or un-hold selected output
DISABLE
Disable function key or digital input
RST FN
Set the function key or digital input
to reset a value
RESET
Reset min, max, or max/min PV
R MIN.MAX
Reset max and min PV value
HINT
Display hint text on key press and
execute action on next key press
OFF
Turn the hint function off
ON
Turn the hint function on
SYSTEM
Program system settings
AOUTCAL
Calibrate the analog output
DEFAULT
Reset meter to factory defaults
PV 2
Enable the meter to scale a se-
cond PV based on the mA input
DISABLE
Disable dual-scale feature (default)
ENABLE
Enable dual-scale feature
BACKLITE
Enable/disable display backlight
ENABLE
Enable the backlight (default)
DISABLE
Disable the backlight
INFO
View meter software, version, and
model; change the identifier tag
SFT
The software ID number
Parameter
Action/Setting Description
VER
The software version
MODEL
The meter model number
ID.TAG
The meter identifier tag
Press
Enter
to edit tag
ICAL
Internal calibration used for scaling
DISPLAY
Program the meter’s display
UNITS
Change the display units within the
selected unit class
DEC.PT
Change the decimal point location
COMMA
Enable or disable the use of a
comma on the bottom display
ENABLE
Enable comma (default)
DISABLE
Disable comma
BARGRAPH
Enable or change the bargraph
PV
(
1
or
2
)
Set the bargraph to display the PV
percentage of full scale
OFF
Turn the bargraph feature off
TOP
Set what to display on the top line
PV
(
1
or
2
)
Display the process variable
PV+UNIT
(
1
or
2
)
Display the process variable and
units alternating
PV+TAG
(
1
or
2
)
Display the process variable and
tag alternating
TAG+UNIT
Display tag and units alternating
PV+U+TAG
(
1
or
2
)
Display the process variable, unit,
and tag alternating
PV1+PV2
Display both process variables
(dual-scale only; see
PV 2
under
advanced features menu)
TAG
Display the tag
STPWATCH
Display the stopwatch
TIMR OC1
Display open collector 1 timer
TIMR OC2
Display open collector 2 timer
TIMER R1
Display relay 1 timer
TIMER R2
Display relay 2 timer
MIN
Display minimum value
MAX
Display maximum value
MIN MAX
Display alternating min and max
OFF
Turn top line off
UNITS
Display the units
BOTTOM
Set what to display on the bottom
line
UNITS
Display the units
PV
(
1
or
2
)
Display the process variable
PV+UNIT
(
1
or
2
)
Display the process variable and
unit alternating
PV+TAG
(
1
or
2
)
Display the process variable and
tag alternating
TAG+UNIT
Display the tag and unit alternating
PV+U+TAG
(
1
or
2
)
Display the process variable, unit,
and tag alternating
PV1+PV2
Display both process variables
(dual-scale only; see
PV 2
under
advanced features menu)
TAG
Display the tag
STPWATCH
Display the stopwatch