Flow 050624-1 Installation Manual Download Page 9

 

 

Installing the HyPlex® Prime Minor Maintenance Kit 

SB-0258  Rev A   Status: PRODUCTION 

 

9 of 10

 

 2011  Flow International Corporation 

UNCONTROLLED COPY 

PRINTED 7/29/11

 

 

Load the tie rods & manifold 

1.

 

Install the pressure loading tool onto the tie rods by running down the tool studs onto 
the exposed threads of the tie rods.  

When tightening, alternate between opposite studs to avoid binding. Tighten the tool 
studs firmly in order to seat the tool piston fully into the tool body, and against the end 
cap as shown below. 

Notes:

  

 

The plunger of the 
pressure loading tool 
must be threaded all the 
way out in order to 
fully seat the piston 
within the cylinder. 

 

When engaged on the tie rods, there 
should be no exposure of the piston 
shoulder. 

 

2.

 

Use a socket wrench to turn the loading tool 
plunger clockwise until the gauge reads  

1500 bar

3.

 

Run the primary nuts of the pump down by hand until firmly seated against the end caps. These 
nuts must be fully bottomed-out against the washers/end caps. 

Note: 

Do not use wrenches when threading 

the primary nuts down. 

4.

 

Use the socket wrench to remove pressure 
from the tool. The gauge will read 

0 bar

 

when pressure has been removed. 

5.

 

Back out all four of the tool studs to 
remove the tool from the tie rods. 

Note: 

When loosening, alternate between 

opposite studs to avoid binding. 

6.

 

Repeat steps 1–5 for the remaining 
positions. 

7.

 

Apply Blue Lubricant to each of the threads on the 3/8 in. high-pressure glands.  

8.

 

On each end of the tube, slide a gland on and thread a collar (A-2839) on the threaded ends of the 
tube. 

9.

 

Repeat Steps 33

35 for the remaining two high-pressure tubes. 

10.

 

Insert one end of the tube into the high-pressure port on the manifold and loosely thread the glands. 
Repeat for the other two high-pressure tubes. 

11.

 

Loosely thread the other end of each of the three tubes into the end cap ports.  

12.

 

Once in place, tighten all six gland nuts. 

13.

 

Reconnect all high-pressure and low-pressure interface connections. 

Summary of Contents for 050624-1

Page 1: ...need the following tools Pressure loading tool 049512 1 Combination wrenches 14 32 mm in drive socket set 14 32 mm in torque wrench 10 200 ft lb Note you may need two wrenches Pry bar set Screwdriver...

Page 2: ...to access the tie rods Place the manifold and PCV assembly combination aside Unload the tie rods with the pressure loading tool 3 Make sure the pressure loading tool plunger is fully retracted Instal...

Page 3: ...if needed 9 Repeat steps 3 through 8 for the remaining positions For each of the three high pressure cylinders 10 Remove the end cap high pressure cylinder inlet poppet springs filler tube and sleeve...

Page 4: ...let poppet seat Discard the poppet seat guide and spring Lap inlet face of check valve body 18 Use the glass lapping plate from the tool kit and lapping paper from the repair kit 19 Lightly wet the pa...

Page 5: ...lace the outlet poppet spring around the guide The spring should be loose on the guide 3 Place the assembly into the outlet cage along with the outlet poppet seat 4 Hold the outlet cage assembly uprig...

Page 6: ...r With a torque wrench and plunger nut tool check plunger nut torque Torque should be 20 ft lb 27 N m 3 Rotate the sheave to fully extend the next plunger to be checked Repeat Steps 1 3 for the other...

Page 7: ...Make sure the plungers are clean and free of any damage or scratches before installing the dynamic seal carriers The subplate adapter seal carrier interface must be clean and free of debris 4 Slide t...

Page 8: ...d cap spring back while installing If it does the inlet poppet can be pinched causing damage The split bearings must be completely seated in the end cap Incorrect installation will cause inappropriate...

Page 9: ...til firmly seated against the end caps These nuts must be fully bottomed out against the washers end caps Note Do not use wrenches when threading the primary nuts down 4 Use the socket wrench to remov...

Page 10: ...nd completely drain the oil 2 Re install the drain plug or oil temperature sensor and fill the crankcase with recommended oil refer to Chapter 1 of your service manual 3 For HyPlex Prime Plus only Cli...