Installing the HyPlex® Prime Minor Maintenance Kit 

SB-0258  Rev A   Status: PRODUCTION 

 

8 of 10

 

 2011  Flow International Corporation 

UNCONTROLLED COPY 

PRINTED 7/29/11

 

Assemble the filler tube  

The filler tube sleeve helps align the poppet with the check valve body and prevents pinching of the 
poppet between the check valve and the filler tube during assembly. 

1.

 

Place the compression spring into the tapered end 
of the filler tube. 

2.

 

Insert the filler tube, spring end first, into the 
high-pressure cylinder, making sure to engage 
the spring into the dynamic seal. 

Repeat for remaining filler tubes. 

3.

 

Insert the inlet poppet assembly into the filler 
tube, spring end first. 

4.

 

Partially install the filler tube sleeve so that it 
surrounds the inlet poppet and spring. 

Repeat for remaining filler tubes. 

 

 

Install the end cap  

CAUTION 

It is important that you do not let the end cap spring back while 

installing. If it does, the inlet poppet can be pinched, causing damage. 

The split bearings must be completely seated in the end cap. Incorrect  

installation will cause inappropriate loading of the high-pressure position. 

 

1.

 

Make sure all eight of the end cap split bearings 
(bushings) are in position. 

2.

 

Align the end cap so it will slide over the tie rods, then 
carefully slide the end cap back until the check valve 
makes contact with the inlet poppet. 

3.

 

Continue to slide the end cap back until the high-pressure 
cylinder engages the o-ring in the end cap and the check 
valve seats against the high-pressure cylinder. 

4.

 

Temporarily install one of the hex nuts, hand tight, to 
prevent the end cap from springing back. 

Follow Steps 1-4 to install the other two end caps, then 
continue with Step 5. 

5.

 

Apply anti-seize compound to both sides of the washers and to the tie rod threads. 

6.

 

Install washers and hex nuts hand tight.  

7.

 

Remove the temporarily installed hex nuts. Apply anti-seize to both sides of the washers and 
threads, then reinstall the nuts. 

Summary of Contents for 050624-1

Page 1: ...need the following tools Pressure loading tool 049512 1 Combination wrenches 14 32 mm in drive socket set 14 32 mm in torque wrench 10 200 ft lb Note you may need two wrenches Pry bar set Screwdriver...

Page 2: ...to access the tie rods Place the manifold and PCV assembly combination aside Unload the tie rods with the pressure loading tool 3 Make sure the pressure loading tool plunger is fully retracted Instal...

Page 3: ...if needed 9 Repeat steps 3 through 8 for the remaining positions For each of the three high pressure cylinders 10 Remove the end cap high pressure cylinder inlet poppet springs filler tube and sleeve...

Page 4: ...let poppet seat Discard the poppet seat guide and spring Lap inlet face of check valve body 18 Use the glass lapping plate from the tool kit and lapping paper from the repair kit 19 Lightly wet the pa...

Page 5: ...lace the outlet poppet spring around the guide The spring should be loose on the guide 3 Place the assembly into the outlet cage along with the outlet poppet seat 4 Hold the outlet cage assembly uprig...

Page 6: ...r With a torque wrench and plunger nut tool check plunger nut torque Torque should be 20 ft lb 27 N m 3 Rotate the sheave to fully extend the next plunger to be checked Repeat Steps 1 3 for the other...

Page 7: ...Make sure the plungers are clean and free of any damage or scratches before installing the dynamic seal carriers The subplate adapter seal carrier interface must be clean and free of debris 4 Slide t...

Page 8: ...d cap spring back while installing If it does the inlet poppet can be pinched causing damage The split bearings must be completely seated in the end cap Incorrect installation will cause inappropriate...

Page 9: ...til firmly seated against the end caps These nuts must be fully bottomed out against the washers end caps Note Do not use wrenches when threading the primary nuts down 4 Use the socket wrench to remov...

Page 10: ...nd completely drain the oil 2 Re install the drain plug or oil temperature sensor and fill the crankcase with recommended oil refer to Chapter 1 of your service manual 3 For HyPlex Prime Plus only Cli...

Reviews: