Rue J.H. Cool 19a | B-4840 Welkenraedt | BELGIUM
Tel. : +32 (0)87 899 799 | Fax : +32 (0)87 899 790
E-mail : [email protected] | www.flow-tronic.com
-
14 -
Figure 7: Wall installation
1
Distance from crown of pipe to wall bracket
3.2.2.2
Attach the sensor to the mounting hardware
The sensor is equipped with 4 threads (M5) to be attached to the mounting hardware. Attach the rotative handle or
the ball mount to the sensor. The sensor can be removed from the frame and installed without entering the
manhole when installed with the one-time entry mounting hardware.
Procedure
1.
Make sure that the cable is tightly connected to the sensor.
2.
Locate the 4 threads on the sensor forseen to attach the ball mount or the rotative handle.
3.
Attach the ball mount or the rotative handle to the sensor using a screwdriver and the 4 M5 screws
delivered with the hardware.
4.
Loosen the wing nut from the ball mount of the mounting hardware.
5.
Insert the ball mount from the sensor and thighten the wing nut so that the sensor stays attached to the
mounting hardware.