Flotec FPSE2800A Owner'S Manual Download Page 6

Warranty

6

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

ATTACH ORIGINAL RECEIPT HERE FOR WARRANTY CONSIDERATION.

FLOTEC warrants to the original consumer purchaser (“Purchaser”) of its products that they are free from defects in
material or workmanship.

If within twelve (12) months from the date of the original consumer purchase any such product shall prove to be defec-
tive, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth below. Your origi-
nal receipt of purchase is required to determine warranty eligibility.

Exceptions to the Twelve (12) Month Warranty

Product

Warranty Period

Drill Pump, Pitcher Pump,

90 days

In-line Water Filter Cartridge

1/3 HP Submersible Sump Pumps
I

NTELLI

P

UMP

(Model FP0S1775A)

2 Years

Back-up Sump Pump System (Model FP2800DCC)

4" Submersible Well Pumps
1/2 HP Submersible Sump Pumps

3 Years

Models FPSC2200A-10 and FPSC2250A-10

Pre-Charge Water System Tank

5 Years

Models FPSC3200A-10 and FPSC3250A-10

Floodmate

®

7000 (Model FP0S6000A)

Ironmate

®

(Model FPSC4550A)

Sewage Ejector (Model FPSE3601A)

Lifetime

Pedestal Sump Pump (Model FPPSS5000)
Utility Pump (Model FPSC1725X)
Submersible Sump Pump (Model FPSC4550A-10)

General Terms and Conditions

Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty
shall not apply to acts of God, nor shall it apply to products which, in the sole judgement of FLOTEC, have been subject
to negligence, abuse, accident, misapplication, tampering, alteration; nor due to improper installation, operation, mainte-
nance or storage; nor to other than normal application, use or service, including but not limited to, operational failures
caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended
maximums.

Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to
FLOTEC as soon as possible after the discovery of any alleged defect. FLOTEC will subsequently take corrective action
as promptly as reasonably possible. No requests for service under this warranty will be accepted if received more than
30 days after the term of the warranty.

This warranty sets forth FLOTEC’s sole obligation and purchaser’s exclusive remedy for defective products.

FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHAT-
SOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES.
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICA-
BLE EXPRESS WARRANTIES PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long
an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific
legal rights and you may also have other rights which vary from state to state.

FLOTEC • P.O. Box 342 • Delavan, WI U.S.A. 53115

Phone: 1-800-365-6832 • Fax: 1-800-526-3757

E-Mail: [email protected] • Web Site: http://www.flotecwater.com

Summary of Contents for FPSE2800A

Page 1: ...h Pages 2 6 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Français Pages 7 11 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 365 6832 Español Paginas 12 16 P O Box 342 Delavan WI 53115 Phone 1 800 365 6832 Fax 1 800 5...

Page 2: ... fuses Do not stand in water or put your finger in fuse socket 5C Do not modify cord and plug When using cord and plug plug into a grounded outlet only When wiring to a system control connect pump ground lead to system ground 6 Do not run pump dry Dry running can overheat pump causing burns to anyone handling it and will void warranty 7 Pump normally runs hot To avoid burns when ser vicing pump al...

Page 3: ... into an electrical outlet Connect or wire pump to an individual branch circuit with no other outlets or equipment in the circuit Size fuses or circuit breakers according to chart below Risk of electrical shock and fire Be sure that power supply information Voltage Hertz Phase on pump motor nameplate matches incoming power supply exactly Install pump according to all electrical codes that apply OP...

Page 4: ...8 FPSE3200A 08 No Description Qty 115 Volt 115 Volt 1 Lower Volute 1 PW1 12P PW1 11P 2 Impeller 1 PW5 13P PW5 15P 3 Upper Volute 1 PW1 10P PW1 10P 4 Power Cord 1 PS117 51 TSE PS117 53 TSE 5 Automatic Float Switch 1 PS17 92 FP18 15BD 4 3 2 1 5 REPAIR PARTS LIST 2800A 3200A SERIES IF MOTOR FAILS REPLACE PUMP ...

Page 5: ...ely disconnect from power source for 30 minutes to allow motor to cool then reconnect to power source Check for cause of overheating overloading 1 Be sure all valves in discharge valve are fully open 2 Clean out discharge pipe and check valve 3 Check for blockage in pump inlet or impeller 4 Pump not sized properly A higher capacity pump may be required 1 Check switch or controller automatic floats...

Page 6: ...t misapplication tampering alteration nor due to improper installation operation mainte nance or storage nor to other than normal application use or service including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning...

Page 7: ...on du cordon et du connecteur ne les enficher que dans une prise de courant reliée à la terre Lorsque la connexion se fait vers le boîtier de commande du système relier le fil de masse de la pompe à la prise de terre du système 6 Ne pas faire fonctionner la pompe à vide Faire fonctionner la pompe sans eau risque de la faire surchauffer et de causer ainsi des brûlures et annule la garantie 7 La pom...

Page 8: ...ant Brancher le connecteur ou directement les fils de la pompe sur circuit de dérivation individuel spécifique libre de tout autre équipement ou prise de courant Sélectionner fusibles ou dis joncteur en fonction du tableau ci dessous Risque d électrocution et d incendie S assurer que les informations relatives à l alimentation tension fréquence en Hertz phase sur la plaquette d identifica tion de ...

Page 9: ...E2800A 08 FPSE3200A 08 No Description Qté 115 Volt 115 Volt 1 Volute inférieure 1 PW1 12P PW1 11P 2 Rotor 1 PW5 13P PW5 15P 3 Volute supérieure 1 PW1 10P PW1 10P 4 Cordon d alimentation 1 PS117 51 TSE PS117 53 TSE 5 Contact flotteur autom 1 PS17 92 FP18 15BD 4 3 2 1 5 LISTE DES PIÈCES DE RECHANGE 2800 3200A Série SI LE MOTEUR TOMBE EN PANNE REMPLACER LA POMPE ...

Page 10: ... minutes pour permettre au moteur de refroidir puis rebrancher l alimentation Rechercher la cause de la surchauffe de la surcharge 1 Vérifier si toutes les valves de la valve de refoulement sont complètement ouvertes 2 Nettoyer le tuyau d évacuation et vérifier la valve 3 Vérifier si la crépine d entrée ou le rotor ne sont pas bloqués 4 La capacité de la pompe ne convient pas Il est peut être néce...

Page 11: ...ui n ont pas été installés utilisés entreposés ou entretenus correctement ni à ceux qui n ont pas été utilisés ou entretenus normalement y compris mais sans s y limiter aux produits ayant des pan nes de fonctionnement causées par la corrosion la rouille ou autre corps étranger dans le système ou à des produits ayant fonctionné à des pressions dépassant la limite maximale recommandée Les demandes d...

Page 12: ...biar los fusibles No trabaje con los pies en el agua ni introduzca sus dedos en el zócalo del fusible 5C No modifique el cable y el enchufe Si usa cable con enchufe utilice sólo una toma con conexión a masa Si conecta a un sistema de control ponga a tierra el cable conector de tierra de la bomba 6 No haga funcionar la bomba en seco El funcionamiento en seco sobrecalienta la bomba puede causar quem...

Page 13: ...a debe conectarse a su propio un ramal individual y no deben colocarse otras tomas o equipo en ese circuito Los fusibles o disyuntores de circuito deben tener la capacidad que se indica en el cuadro que figura más abajo Peligro de descarga eléctrica e incendio Asegúrese de que la información sobre la corriente eléctrica voltaje frecuencia y número de fases inscrita en la chapa del motor de la bomb...

Page 14: ...00A 08 Réf de piezas Cantidad 115 Volt 115 Volt 1 Voluta inferior 1 PW1 12P PW1 11P 2 Rodete 1 PW5 13P PW5 15P 3 Voluta superior 1 PW1 10P PW1 10P 4 Cable de alimentación 1 PS117 51 TSE PS117 53 TSE 5 Interruptor automático de flotador 1 PS17 92 FP18 15BD 4 3 2 1 5 LISTA DE PIEZAS DE REPUESTO 2800A 3200A SERIE SI EL MOTOR FALLA REEMPLACE LA BOMBA ...

Page 15: ... motor se enfríe luego vuelva a conectarla a la corriente eléctrica Investigue la causa del sobrecalentamiento o sobrecarga 1 Asegúrese de que todas las válvulas en la tubería de descarga estén totalmente abiertas 2 Limpie el caño de descarga y verifique la válvula 3 Verifique que la entrada de la bomba o el rodete no estén bloqueados 4 Quizás la bomba no tenga el tamaño correcto y es posible que ...

Page 16: ...ciones contraindicadas mane jo indebido alteraciones ni debido a instalación funcionamiento mantenimiento o almacenaje incorrectos ni a ningu na otra cosa que no sea su aplicación uso o servicio normales incluyendo pero no limitado a fallas operacionales causadas por corrosión oxidación u otros elementos extraños en el sistema o funcionamiento a presión por encima del máximo recomendado Los pedido...

Reviews: