Troubleshooting 7

For parts or assistance, call Flotec Customer Service at 1-800-365-6832

 Risk of electrical shock. Unplug the pump before touching it or servicing it.

Symptom

Probable Cause(s)

Corrective Action

Pump won’t start 

or run.

Pump is not plugged in.

Make sure the pump is plugged into a proper outlet.

Blown fuse.

Replace the fuse with a fuse of proper size.

Low line voltage.

Check the size of the wiring on the circuit feeding the pump and 

from the main switch on the property. If everything is OK, contact 

your power company or hydro authority.

Defective motor.

Replace the pump.

Defective float switch.

Replace the float switch.

Clogged or jammed Impeller.

If the impeller won’t turn, unplug the pump, remove the lower 

pump body, and locate the source of the binding. Replace the 

impeller if necessary.

Pump starts and 

stops too often.

Backflow of water from piping.

Install or replace the check valve.

Faulty switch.

Replace the switch.

Pump won’t 

shut off.

Defective switch.

Replace the switch, after first checking that switch is functional.

Restricted discharge (obstacle or 

ice in the piping).

Unplug the pump, remove it from the sump, and clean the pump 

and piping.

Restricted intake screen.

Unplug the pump, remove it from the sump, and clean the intake 

screen and impeller.

Pump operates 

but delivers little 

or no water.

Low line voltage.

If the voltage is below 110 volts, check the size of the wiring 

from the main switch on the property. If OK, contact your power 

company or hydro authority.

Debris caught in the impeller.

Remove the pump and clean out the impeller.

Worn or defective parts or 

plugged impeller.

Clean the impeller if it’s plugged; replace the impeller if 

necessary; otherwise replace the pump.

Check valve installed without 

vent hole

Drill a 1/8” (3mm) dia. hole between the pump discharge and 

the check valve (1-2” above the pump discharge and below the 

waterline).

Restricted intake screen.

Remove the pump and clean out the intake screen.

Check valve is installed either 

backward or upside down.

Be sure the check valve is installed correctly (the flow arrow 

should point away from the pump).

Summary of Contents for E50TLT

Page 1: ...tion Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 10 17 Instalaci n Operaci n Piezas Para mayor in...

Page 2: ...h present If any oil leaks out of the motor it can kill fish 3 Drain the system completely before servicing it 4 To prevent a flexible discharge line from whipping which could cause injury or damage f...

Page 3: ...e hole is below the waterline and below the check valve 2D To reduce noise and vibration cut the discharge pipe near the pump and fasten a short length of rubber hose 1 7 8 48 mm I D e g radiator hose...

Page 4: ...Can shock burn or kill Always ground the pump to a suitable electrical ground such as a grounded water pipe a properly grounded metallic raceway or a ground wire system Do not cut off the round groun...

Page 5: ...are running the pump manually and water stops coming out of the discharge the pump has probably run dry Shut it off immediately and check the water level Sump Pit Check Valve Install Vertically Baseme...

Page 6: ...50TLT E50VLT E75VLT Ref Part Description Qty E50TLT E50VLT E75VLT 1 Power Cord Assembly 1 PW117 281 TSU 2 Impeller 1 PS5 33P PS5 34P 3 Vertical Float Switch Ass y 1 PKG208 4 Tethered Float Switch Ass...

Page 7: ...shut off Defective switch Replace the switch after first checking that switch is functional Restricted discharge obstacle or ice in the piping Unplug the pump remove it from the sump and clean the pu...

Page 8: ...Step 3 Thread the new impeller onto the motor shaft as shown left hand thread tightens to the left Step 4 Re mount the motor on the base Be sure to mount it so that the switch is clear of the dischar...

Page 9: ...Contact FLOTEC Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For...

Reviews: