Operation 5
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
1. The shaft seal depends on water for
lubrication. Do not operate the pump unless
it is submerged in water; running it dry may
damage the seal.
2. If the pump overheats, an automatic-reset
thermal protector cuts off the power and stops
the motor before it can be damaged. The motor
will automatically restart when it cools. If the
protector trips repeatedly, unplug the pump,
remove it from the sump, and check it for
the cause of the difficulty. Low voltage, long
extension cords, clogged impeller, very low lift,
a plugged or frozen discharge pipe, etc., can
all cause cycling and overheating.
3. This pump will not remove all the water in the
sump. If you are running the pump manually
and water stops coming out of the discharge,
the pump has probably run dry. Shut it off
immediately and check the water level.
Sump
Pit
Check Valve
(Install Vertically)
Basement
Floor
Discharge
Pipe
Lift
6207 0410
Figure 7 – LIFT: Lift is the vertical distance the
pump actually lifts water. The higher the lift, the
lower the flow.
NOTICE The friction caused by water running
through the pipe will also, on longer pipe runs,
reduce the flow. Pipe smaller than the pump
discharge also reduces flow.
Performance
GPH At Total Feet Of Lift
Model
5 ft.
10 ft.
15 ft.
20 ft.
No flow at
height shown
below
Capacity Gallons/Hour
E50TLT
4,320 3,660 2,640 1,020
22’
E50VLT
E75VLT
4,800 4,020 3,180 1,800
25’
Electrical & Switch Specifications
Model
Motor HP
Motor Full Load
Amps
Individual Branch
Circuit Req. (Amps)
*Switch Setting in inches
Water Level For:
On
Off
E50TLT
1/2
6.9
15
13-1/2”
4-1/2”
E50VLT
7-1/2”
3”
E75VLT
3/4
7.0