Chap. 4 Installation  (see Fig. 1-3)

 

GB

3

If the pump is fixed in a permanent location with rigid pipes, it is advisable to install a quick closing fitting in the most 

convenient location to facilitate cleaning and maintenance.

The pumps used in ponds, small lakes, fountains or similar installations or close to them should have a safety switch. 

Contact a specialised electrician.

To use the pump for temporary applications, install a flexible pipe and connect it to the pump using a pipe holder. To 

immerse the pump, use a rope and fix it to the handle.

The fitting supplied with FLOTEC ComPac pumps can be adapted to the dimensions of the 

pipe used. 

To connect a threaded pipe or a 3/4" (19 mm) quick closing fitting, tighten it directly on the 

threaded part (location a).

When using a Ø 25 mm (1") pipe, cut the stage that is not being used at the correct height 

(up to point b).

When using a Ø 32 mm (1 1/4"), cut the stages that are not being used at the correct height 

(up to point c).

FLOTEC ComPac pumps come with a check valve that prevents the delivery pipe from being drained and the fluid from 

recirculating. 

The dimensions of the collection chamber should allow the insertion of the pump and reduce to the minimum the start-

up operations per hour (see LIMITATIONS - Technical data).

Connection of the delivery pipe

a

b

c

1. Remove the part that is not being used from the standard fitting cutting it with a knife.

2. Tighten the standard fitting on the pump.

3. Connect the pipe to the standard fitting.

In outdoor fountains, garden ponds and similar places the pump is to be supplied through a residual current device (RCD) 

having a rated residual operating current not exceeding 30mA. If these pumps are used in continuous mode for ponds 

with fish, it is necessary to check them at regular intervals of 6 months (if the water contains aggressive substances). 

It is also advisable to check the maximum dimension of particles recommended for the pump and take the necessary 

measures to prevent the fish from being sucked into the pump.  

Grounding

The plug of the power cable has a double grounding contact, so that grounding can be performed by simply inserting 
the plug.  

The installer must make sure that the electric system is grounded in accordance with the law 

in force.

Chap. 5 Electric Connection

Verify that the voltage and frequency of the electropump shown on the nameplate correspond to 

those available on the mains.

Make sure that the electric system has  a high-sensitivity circuit breaker

 

 

30 mA (DIN VDE 

0100T739).

The power cable must be replaced by qualified personnel only.

GB

Use the handle provided to transport or lift the pump.

Electric shock 

risk

DANGER

To prevent possible injuries to people, avoid inserting hands into the mouth of the pump if 
this is connected to the mains.

DANGER

When installing, please ensure electropump is disconnected from electrical 

supply. Pumps in this series are not suitable for use in a swimming pool and 

the relevant cleaning and servicing operations.