Electrical
6
For parts or assistance, call Flotec Customer Service at
1-800-365-6832
Hazardous voltage. Can shock, burn,
or cause death.
Ground pump before connecting to
power supply.
Ground motor before connecting to electrical
power supply. Failure to ground motor can cause
severe or fatal electrical shock hazard.
Do not ground to a gas supply line.
To avoid dangerous or fatal electrical shock, turn
OFF power to motor before working on electrical
connections.
Ground Fault Circuit Interrupter (GFCI) tripping
indicates an electrical problem. If GFCI trips and
will not reset, have a qualified electrician inspect and
repair electrical system.
Exactly match supply voltage to nameplate volt-
age. Incorrect voltage can cause fire or seriously
damage motor and voids warranty. If in doubt consult a
licensed electrician.
Voltage
Voltage at motor must be not more than 10% above or
below motor nameplate rated voltage or motor may
overheat, causing overload tripping and reduced compo-
nent life. If voltage is less than 90% or more than 110%
of rated voltage when motor is running at full load, con-
sult power company.
Grounding/Bonding
Install, ground, bond and wire motor according to local
or National Electrical Code requirements.
Permanently ground motor. Use green ground terminal
provided under motor canopy or access plate (See Figure
3); use size and type wire required by code. Connect
motor ground terminal to electrical service ground.
Bond motor to pool structure. Use a solid copper con-
ductor, size No. 8 AWG (8.4 sq.mm) or larger. Run wire
from external bonding lug (see Figure 3) to reinforcing
rod or mesh.
Connect a No. 8 AWG (8.4 sq.mm) solid copper bonding
wire to the pressure wire connector provided on the
motor housing and to all metal parts of the swimming
pool, spa, or hot tub and to all electrical equipment,
metal piping or conduit within 5 feet (1.5 m) of the
inside walls of swimming pool, spa, or hot tub.
A
A
L2
L2
L1
L1
230V
11
5V
Bonding
Lug
Green
Ground
Screw
Figure 3 – Typical ground screw and bonding lug
locations.
Pull plug
straight
out from
terminal
board.
1.
1.
2.
2.
Plug in again
with arrow
on plug
pointing to
'115 Volts'.
A
L1
230 V
olts
1
15
V
olts
A
L1
230 V
olts
1
15
V
olts
Ground
Screw
3962 0401 A
115 V
230 V
230 Volt to 115 Volt Conversion.
Move plug to change voltage.
Ground
Screw
230V
115V
230V
115V
A
A
L2
L2
L1
L1
230V
115V
A
A
L2
L2
L1
L1
230V
115V
Power Supply
Wires
230 Volt to 115 Volt Conversion.
Move plug to change voltage.
Figure 4 – Wiring hook-up diagram, 115/230V dual
voltage.