Page 60 of 64
versatile™ 4C Maintenance Manual—206367—Rev A
www.florencemailboxes.com
Replacement of Top Shelf
versatile™ 4C mailbox suites
REQUIRED TOOLS
1/8” DRILL BIT
PLASTIC MALLET
PNEUMATIC BLIND RIVET GUN
PORTABLE DRILL
TOOLS FROM EARLIER STEPS
1 .
Open the master door(s) using procedures
on pp. 8–13.
2 .
Remove the 4C mailbox module from the
wall or enclosure using procedures on
pp. 14–15.
3 .
Remove the hold-open arm using
procedures on pp. 16–17
4 .
Remove the top trim (and bottom trim on dbl
column modules) using procedures on
pp. 18–19
5 .
If working with a sgl column module, skip to
Step 7.
6 .
If working with a dbl column module, the
two inserts will need to be separated to
gain access to the rivets located between
the inserts. Using a 1/8” drill bit, drill out
1/8” dia x 0.337” SS blind rivets (
86098
)
holding the left-hand insert to the slide
housing, and to the joiner plates on the back
of the unit.
7 .
Using a 1/8” drill bit, drill out 1/8” dia x
0.337” SS blind rivets (
86098
) holding the
shelf in place.
8 .
Using a plastic mallet, apply force
underneath the shelf to be removed,
dislodging it from the metal snaps holding it
to the insert panel.
PART #
DESCRIPTION
86098
1/8” DIA X 0.337” SS BLIND RIVET
K86274
FRONT-LOAD UPPER RIGHT SHELF ASSEMBLY
K86275
FRONT-LOAD UPPER LEFT SHELF ASSEMBLY
NOTE: The top shelves are riveted in place for strength and/or security. Up
to five (5) 1/8” dia x 0.337” SS blind rivets (86098) per shelf must be
removed from below the shelf before replacing the shelf. This will require
removing the module from the wall (see pp. 14–15).
NOTE: This procedure will require opening the master door(s). Contact local
postal officials to gain access to units serviced by the USPS.
9 .
To replace the shelf assembly, with hold-
open latch bracket and hold-open guard
attached, place it above the metal snaps,
align it front to back, and apply force with
a plastic mallet to snap the shelf back into
place.
10 .
Resecure the shelf with 1/8” dia x 0.337”
SS blind rivets (
86098
).
11 .
If working with a sgl column module, skip to
Step 13.
12 .
If working with a dbl column module,
reattach the insert to the slide housing, and
to the joiner plates on the back of the unit.
13 .
Reinstall the top trim (and bottom trim on dbl
column modules) using procedures on
pp. 18–19
14 .
Reinstall the hold-open arm using
procedures on pp. 16–17
15 .
Reinstall the module in the wall or enclosure
using procedures on pp. 14–15.
16 .
Close the master door(s) and lock the
master-access door using procedures on
pp. 8–13.
Confidential & Proprietary for Florence and Clients Only -- Do Not Distribute