FLORABEST FRP 350 B1 Translation Of Original Operation Manual Download Page 11

11

GB IE

housing and become stuck, by using a 

jet of water. 

•  Clean any deposits adhering to the 

floating switch (   5) with clean water.  

Cleaning the filter

In the suction foot, the pump has a remov-

able filter, designed to protect it from dirt. 

According to the level of dirt in the water, 

this should from time to time be checked 

and cleaned when necessary. 

 1.  Unplug the appliance from the 

power supply.

 

2.  Remove the five screws on the un-

derneath of the pump housing (9).

 

3.  Take the suction foot (8) off the 

pump and take out the filter (7).

 

4.  Wash the filter (7) under running 

water and put it back in place.

 

5.  Put the suction foot (8) back on 

the pump and fasten it with the 

five screws. 

Cleaning the impeller wheel

If deposits in the pump housing become 

too heavy, the bottom part of the pump 

must be dismantled as follows. 

1.  Remove the 5 screws on the bottom of 

the pump casing and pull off the suc-

tion foot (  8). 

2.  Unscrew the paddle wheel cover (  

24) (6 screws).

3.  Clean the inside wall of the pump 

housing and the impeller wheel with 

clear water. 

4.  For re-assembly, follow the same 

steps in reverse. 

Storage

•  Store the appliance in a dry, frost-free 

place, and where children cannot gain 

access to it.

•  When the pump is not to be used for 

a longer period, it must be thoroughly 

cleaned after its last use, and before it 

is next used. Otherwise there may be 

problems in starting the pump, caused 

by deposits and residues.  

  -  Wind the mains cable (12) 

around the cable storage area   

(   10). 

 

-  Insert the dismantled aluminium 

tube (13/14/15/19) into the stor-

age compartment (3). 

All other work on the pump, and in particular 

opening it, must be carried out by a special-

ist electrical service engineer. If any repairs 

are necessary, you should always get in 

touch with the Grizzly Service Centre.

Waste disposal and envi-

ronmental protection

Be environmental. Return the tool, acces-

sories and packaging to a recycling centre 

when you are finished with them.

  Machines do not belong with do-

mestic waste. 

Hand over the device at an utilization 

location. The plastic and metal parts em-

ployed can be separated out into pure 

materials and recycling can be implement-

ed. Ask your Service Center (see Page 16) 

about this.

Defective units returned to us will be dis-

posed of for free.

Summary of Contents for FRP 350 B1

Page 1: ...FRP 350 B1 Rain Barrel Pump Translation of original operation manual 6...

Page 2: ...GB IE Translation of original operation manual Page 5 Before reading unfold the page containing the illustrations and familiarise yourself with all functions of the device...

Page 3: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 16 18 19 19 21 14 13 11 4 2 6 12 20 20 22 23 20 21 15 1 5 8...

Page 4: ...2 5 8 7 3 24 12 13 14 15 19 9 5...

Page 5: ...t Read the instructions for use thor oughly Caution If the power supply cable is damaged or cut withdraw the plug from the power socket immedi ately Contents Notes on Safety 5 Symbols in the manual 5...

Page 6: ...of reach of children Caution To avoid damage to the equipment and any possible per son injury resulting from this Do not work with damaged or incom plete equipment or with equipment that has been conv...

Page 7: ...rom the socket by the cable Protect the cable from heat oil and sharp edges Do not carry or fix the equipment by the cable Only use a rubber sheathed cable des ignated H05 RNF for mains connection The...

Page 8: ...Middle aluminium tube 15 Aluminium tube with plastic hook 16 Height adjustment screw 17 Pressure connection for garden hosepipe 18 Shut off tap 19 Flexible tube 20 Cable clips 21 Hook for suspending...

Page 9: ...on the plastic hook 21 and on the middle aluminium tube 14 Mounting the height adjust ment for the float switch 5 Loosen the screw on the float switch height adjustment 2 and push this over the float...

Page 10: ...aware if the automatic cut out operates or the pump runs dry to limit any damage to a minimum Adjusting the float switch Automatic mode The on or off switching point on the float switch 5 can be conti...

Page 11: ...ith clear water 4 For re assembly follow the same steps in reverse Storage Store the appliance in a dry frost free place and where children cannot gain access to it When the pump is not to be used for...

Page 12: ...ur Grizzly Service Centre Repairs which are not covered by the guarantee can be carried out for charge by our service center Our service center will be glad to provide you with a cost estimate We can...

Page 13: ...ater Withdraw the power plug and clean the pump if necessary replacing worn parts Pump does not switch off Float switch 5 cannot sink Check position of the float switch Amount pumped is inadequate Suc...

Page 14: ...r to guarantee consistency the following harmonised standards as well as national standards and stipulations have been applied EN 60335 1 2002 A11 2004 A1 2004 A12 2006 A2 2006 A13 2008 EN 60335 2 41...

Page 15: ...15 GB IE Exploded Drawings informative...

Page 16: ...16 GB IE informative...

Page 17: ...rvice Center DES UK Ltd Unit B7 Oxford Street Industrial Park Vulcan Road Bilston West Midlands WV14 7LF Tel 0870 787 6177 Tel from Ireland 0044 870 787 6177 Fax 0870 7876168 Fax from Ireland 0044 870...

Page 18: ...IAN 61038 Grizzly Gartenger te GmbH Co KG Am Gewerbepark 2 D 64823 Gro Umstadt Last Information Update 12 2010 Ident No 79300622122010 6 6...

Reviews: