![background image](http://html.mh-extra.com/html/flomec/f116-p/f116-p_owners-manual_2306730047.webp)
Page 47
FL_F116P_v1702_01_EN
PDU
ADDRESS
REGISTER VARIABLE
COMMUNICATION
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 144
[h] 0x090
40145
speed (baud rate)
1
r/w
uint16 0: 1200
1: 2400
2: 4800
3: 9600
[d] 145
[h] 0x091
40146
Modbus address
1
r/w
uint16 1…247
[d] 146
[h] 0x092
40147
Modbus mode
1
r/w
uint16 0: ASCII
1: RTU
2: OFF
PDU
ADDRESS
REGISTER VARIABLE
OTHERS
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 173
[h] 0x0AD
40174
model number
1
r
uint16 0…9999
[d] 160
[h] 0x0A0
40161
model suffix
1
r
char
Representation: ASCII character
[d] 162
[h] 0x0A2
40163
firmware version
2
r
uint32 0…999999
Representation: nn:nn:nn
[d] 165
[h] 0x0A5
40166
serial no
2
r
uint32 0…9999999
Representation: nnnnnnn
[d] 168
[h] 0x0A8
40169
password
1
r
uint16 0…9999
[d] 170
[h] 0x0AA
40171
tag-nr
2
r/w
uint32 0...9999999
Representation: nnnnnnn