![Flomec 490 Instruction Manual Download Page 14](http://html1.mh-extra.com/html/flomec/490/490_instruction-manual_2306712014.webp)
13
Calibration
4.3 Calculating K-factors
( litres or m³ )
Calculate K-factor ( pulses / litre ) using the above graph and the metric constant of 1273.2 as
follows :
Pulses / litre
= 1273.2 x
(A)
from graph
pipe ID² (mm)
Example ‘a’ :
K-factor for 100mm pipe:
1)
from graph 100mm ID
(A)
= 24.0
2)
pulses/litre. = 1273.2 x 24.0
10000 =
3.056
p
/
litre
K-factor for m³
:
multiply by 1000 eg. K = 3056 p/m³
K-factor for megalitres
:
multiply by 1000000 eg. K = 3056000 p/megalitre
NOTE :
K-factors for Reed Switch output option are 1/3 the standard factors of voltage pulse
output.