![Flomec 125100-10 Owner'S Manual Download Page 5](http://html1.mh-extra.com/html/flomec/125100-10/125100-10_owners-manual_2306711005.webp)
5
SPECIFICATIONS
Mechanical
Housing material:
Nylon 6/6
Strain relief:
Hubble PG7. Grip range (Cable Outside Diameter)
0.11 - 0.26 in. (2.8 – 6.6 mm)
Housing port thread:
Female 1/2-20 UNF-2B (Compatible with PG7)
Cable
Belden 9363 (22 AWG-3 conductor
with drain wire and shield)
Cable length
10 ft. (3m), provided
Operating Temperature
0° to +140°F (-18° to +60°C)
Higher Process Fluid
Temperatures
Obtainable with G2
Stainless Steel Meters
When installed on G2 Stainless Steel Flowmeters, see
Ambient and Fluid Temperature Limits graph on next page
for higher process fluid temperature Limits.
If wider process fluid temperature ranges are desired,
reference information on FLOMEC® Remote Kits.
Storage temperature:
-40° to +180°F (-40° to +82°C)
Power:
Type:
Loop powered
Voltage minimum:
8 VDC
Voltage maximum:
32 VDC
Isolated:
No
Primary Output (4-20mA):
Type:
Loop
Minimum:
4 mA
Maximum:
25 mA
Scaled Pulse Output:
Type:
Open Collector (NPN), Current Sinking
External Pull Up
Voltage
1
8.0 to 26 VDC
Internal Pull Up Voltage
2
5.0 VDC
1
NOTE:
Customer supplied external voltage with separate power supply and a minimum
external pull up resistance of 820 ohms.
2
NOTE:
5VDC supplied internal on the 4-20mA board, no external supply or pull up
resistor required. Internal pull up is fixed at 100K ohm