FLOMEC®  TWO-YEAR  LIMITED  WARRANTY 

Great Plains Industries, Inc. 5252 E. 36th Street North, Wichita, KS USA 67220-3205, hereby 
provides  a  limited  warranty  against  defects  in  material  and  workmanship  on  all  products 
manufactured  by  Great  Plains  Industries,  Inc.  This  product  includes  a  2-year  warranty. 
Manufacturer’s  sole  obligation  under  the  foregoing  warranties  will  be  limited  to  either,  at 
Manufacturer’s  option,  replacing  or  repairing  defective  Goods  (subject  to  limitations 
hereinafter provided) or refunding the purchase price for such Goods theretofore paid by the 
Buyer, and Buyer’s exclusive remedy for breach of any such warranties will be enforcement 
of  such  obligations  of  Manufacturer.  The  warranty  shall  extend  to  the  purchaser  of  this 
product and to any person to whom such product is transferred during the warranty period. 

The warranty period shall begin on the date of manufacture or on the date of purchase with 
an original sales receipt. This warranty shall not apply if: 

A.  the  product  has  been  altered  or  modified  outside  the  warrantor’s  duly  appointed 

representative; 

B.  the product has been subjected to neglect, misuse, abuse or damage or has been 

installed  or  operated  other  than  in  accordance  with  the  manufacturer’s  operating 
instructions. 

To make a claim against this warranty, or for technical assistance or repair, contact your 
FLOMEC distributor or contact FLOMEC at one of the locations below. 
 

In North or South America contact 

 

Great Plains Industries, Inc. 

5252 East 36

th

 St. North  

Wichita, KS  67220-3205 

 USA 

 

888-996-3837 

 

www.flomecmeters.com 

(North America)

 

Outside North or South America contact 

 

GPI Australia 

(Trimec Industries Pty. Ltd.) 

12/7-11 Parraweena Road 

 Caringbah NSW 2229 

Australia 

 

+61 02 9540 4433 

 

www.flomec.com.au

 

The  company  will  step  you  through  a  product  troubleshooting  process  to  determine 
appropriate corrective actions. 

GREAT  PLAINS  INDUSTRIES,  INC.,  EXCLUDES  LIABILITY  UNDER  THIS  WARRANTY 
FOR DIRECT, INDIRECT, INCIDENTAL AND CONSEQUENTIAL DAMAGES INCURRED IN 
THE USE OR LOSS OF USE OF THE PRODUCT WARRANTED HEREUNDER. 

The company herewith expressly disclaims any warranty of merchantability or fitness for any 
particular purpose other than for which it was designed. 

This warranty gives you specific rights and you may also have other rights which vary from 
U.S. state to U.S. state. 

NOTE: In compliance with MAGNUSON MOSS CONSUMER WARRANTY ACT – Part 702 
(governs the resale availability of the warranty terms). 

 
 
 
 

© 2021 Great Plains Industries, Inc., All Rights Reserved. 

Great Plains Industries, Inc. / 888-996-3837 / flomecmeters.com 

 
 
09/2021   

 

 

 

 

 

920907-01 Rev. C 

Summary of Contents for 125100-10

Page 1: ...n installed on G2 1 stainless steel flowmeter 4 20mA MODULE FOR USE WITH MOST FLOMEC TURBINE METERS WITH Q9 DISPLAY FLOMEC QSE meters have their own 4 20mA module 09 2021 920907 01 Rev C Product Owner s Manual EN NN ...

Page 2: ...o back cover for information regarding this product s warranty and other important information DO NOT RETURN THIS PRODUCT TO THE STORE Please contact Great Plains Industries Inc before returning any product If you are missing parts or experience problems with your installation contact our Customer Support Department We will be happy to assist you Call 888 996 3837 or 316 686 7361 Email meters gpla...

Page 3: ...ONTENTS Getting Started 4 Electrical Mechanical Specifications 5 Approval Ratings 7 Installation 8 Installing Module 8 Wiring 9 Operation Calibration 11 Troubleshooting 12 Parts List 15 Parts Service 15 Warranty 16 ...

Page 4: ...C meters that are equipped with the Q9 display option The 4 20mA module can be field calibrated through the configuration menu options on the Q9 display FLOMEC QSE meters have their own 4 20mA module UNPACKING INSPECTION Inspect After unpacking the unit inspect carefully for any damage that may have occurred during transit Check for loose missing or damaged parts Shipping damage claims must be fil...

Page 5: ...e for higher process fluid temperature Limits If wider process fluid temperature ranges are desired reference information on FLOMEC Remote Kits Storage temperature 40 to 180 F 40 to 82 C Power Type Loop powered Voltage minimum 8 VDC Voltage maximum 32 VDC Isolated No Primary Output 4 20mA Type Loop Minimum 4 mA Maximum 25 mA Scaled Pulse Output Type Open Collector NPN Current Sinking External Pull...

Page 6: ...6 SPECIFICATIONS continued AMBIENT AND FLUID TEMPERATURE LIMITS NOTE The upper limit of the Useable Combination area can be increased by 10 F 6 C when lithium batteries are installed in the Q9 Display ...

Page 7: ...2 mm Module shown installed on G2 1 stainless steel flowmeter Figure 1 Note This 4 20mA module is designed for use with most FLOMEC meters that are equipped with the Q9 display option The 4 20mA module can be field calibrated through the configuration menu options on the Q9 display FLOMEC QSE meters have their own 4 20mA module APPROVAL RATINGS ...

Page 8: ...A and scaled pulse output to function 2 Disconnect 2 pin coil connector from display Make sure coil remains firmly attached to meter body DO NOT pull on wires or attempt to remove from meter body 3 Connect the 4 20mA Module to the 10 pin connector located on the backside of the computer electronics see Figure 2 4 Reconnect the coil connector to the 2 pin terminal block on the other end of the comp...

Page 9: ...output on the White wire with the cable shield as the ground return This is set to raw pulse output as the default setting on the Q9 display If your application requires a scaling of the pulse output refer to the installation instructions to enable the scaled pulse feature and refer to the Q9 owner s manual for instructions on the configuration of the scaled pulse feature NOTE If using the scaled ...

Page 10: ...board see Figures 4a 4b When the Jumper is on the top two pins the external resistor required option is selected Figure 4a This external resistor can be installed as shown on Figure 3 but could also be built into the existing customer equipment When the Jumper is located on the bottom two pins the internal resistor option is selected Figure 4b Figure 4a Figure 4b ...

Page 11: ...Section for further instructions NOTE The Q9 Display controls the 4 20 mA settings It is recommended to verify and set if necessary the most optimal Calibration Method of the Q9 Display see Q9 Owner s Manual referenced above before adjusting 4 20mA settings You can download the Q9 Owner s Manual Non Agency here or visit flomecmeters com to download owner s manuals and other technical documents ...

Page 12: ...eck Q9 owner s manual for instructions on how toset ZERO and SPAN for meter 2 Reconfigure 4 20mA Module output signal ZERO and SPAN to match Customer s recording device ZERO and SPAN or vice versa 3 Verify Q9 display value is giving correct flowrate C Scaled Pulse output not working or not shown in Q9 configuration options menu 1 Batteries being installed will disable the Scaled Pulse output featu...

Page 13: ... in Q9 owner s manual 2 If 1 above is not the Issue See Operation Calibration Section of this manual F Q9 display value not giving correct volume totals 1 Q9 display showing velocity flowrate or accumulative total instead of batch total 2 Q9 display calibration is not optimized for best results 1 Press bottom button of Q9 display until correct volume is displayed see Operation Section in Q9 owner ...

Page 14: ...________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ __...

Page 15: ...ed with the following information The model number of your meter The serial number or manufacturing date code of your meter Part descriptions and numbers For warranty work always be prepared with your original sales slip or other evidence of purchase date IMPORTANT Please contact GPI before returning any parts It may be possible to diagnose the trouble and identify needed parts in a telephone call...

Page 16: ...her than in accordance with the manufacturer s operating instructions To make a claim against this warranty or for technical assistance or repair contact your FLOMEC distributor or contact FLOMEC at one of the locations below In North or South America contact Great Plains Industries Inc 5252 East 36th St North Wichita KS 67220 3205 USA 888 996 3837 www flomecmeters com North America Outside North ...

Reviews: