background image

Models R4515-743

Models

R4525-743

Variable Speed Water System

SENSOR VSD™
WATER SYSTEM

FEATURES

• Variable Speed Control
• Solid State Pressure Sensor
• Nearly Silent Operation / No Cycling
• Operates on 12Vdc or 24Vdc
• Controls Pressure by Changing 

Motor Speed

• Speeds Up As Demand Increases
• Self-priming / Runs Dry
• No Accumulator Tank Needed
• CSA Listed / EN ISO 8846 Marine / 

C.E. Certified

• Patent Pending

SPECIFICATIONS

Motor:

Permanent magnet, double ball bearing arma-
ture. Electronic speed control built into rear
endbell.

Pump:

Four chamber positive displacement
diaphragm design. Self-priming up to 10 feet
suction lift. Pump able to run dry without
damage. Removable port adapters.

Mount the pump in a dry, ventilated location. The inlet
strainer must be installed between the fresh water
supply and the pump inlet port. The supply tank should
be at least half full prior to initial operation.

IMPORTANT:

Polarity of electrical connections is very

important. Insure that the RED (+) motor lead is
connected to a fused positive d.c. circuit. The BLACK (-)
motor lead must be connected to the negative DC
circuit. In the event that polarity is reversed fuse found in

the “EMI Filter Box” must be replaced.

Sensor VSD™

pumps require a battery to be installed

in the DC power supply when using an AC to DC
converter or battery charging system.

To prime the plumbing system, open all the faucets and
turn on the power to the pump. Shut off each faucet as
it begins to run free of air. As the last faucet is closed the
pump will slow down and shut off.

OPERATION

AUTOMATIC VARIABLE SPEED MOTOR DRIVEN

Pump Series

Dimensions - Inches (mm)

Weight

Height

Width

Length

lb. (kg)

R4515-743

3.75 (95)

6.3 (160)

9.0 (221)

4.3 (2)

R4525-743

3.75 (95)

6.3 (160) 10.3 (252)

6.3 (3)

Amp Draw

Max

Flow

Sensor

Cut-out

Inlet

Model

Volts

(24V)

Fuse

GPM (LPM)

Pressure

Pressure

Strainer

R4515-743

12-24Vdc

8.0 (4.0)

15A

3.7 (13.5)

25 (1.7 bar)

35 psi (2.4 bar)

Yes

R4525-743

12-24Vdc

12.0 (6.0)

15A

4.5 (16.3)

30 (2.1 bar)

40 psi (2.8 bar)

Yes

Models R4515-743 & R4525-743

Summary of Contents for R4515-743

Page 1: ...T Polarity of electrical connections is very important Insure that the RED motor lead is connected to a fused positive d c circuit The BLACK motor lead must be connected to the negative DC circuit In the event that polarity is reversed fuse found in the EMI Filter Box must be replaced Sensor VSD pumps require a battery to be installed in the DC power supply when using an AC to DC converter or batt...

Page 2: ...PM model Use hose clamps on hose barb connectors STEP 6 OPTION Install a 40 mesh in line strainer in an accessible location between the supply and the pump inlet A INSTALLATION The Automatic Variable Speed Motor Driven Pumps will operate in either a 12 or 24 volt dc system The unique electronics adjust the voltage and current to the motor as needed STEP 1 Use 14 AWG stranded wire to 20 feet 12 AWG...

Page 3: ...tons must be aligned with alignment slots on the cam bearing assembly 2 Drive each Phillips head screw partially tight carefully center each piston in its quadrant and then tighten the screws securely 18 in lbs torque Lower Housing 3 Attach lower housing to motor shaft by aligning indention in shaft with set screw Set screw must align with the shaft indention or major damage poor performance or hi...

Page 4: ...f g n i r i w k c e h C r e w o p o n s a h t i u c r i c p m u P Loose or corroded wiring connection Inspect wire connections t e s e r r o e c a l p e R r e k a e r b n e p o r o e s u f n w o l B Open thermal protector motor shell hot Wait 20 to 30 minutes for auto reset Defective motor drive control or pressure sensor Contact factory 1 800 2FLOJET Pump fails to turn off after all fixtures are ...

Reviews: