background image

C

A

B

Red (+)

Fuse

(+)

Switch

Battery

Black (

)

-

)

-

)

INSTALLATION

WIRING

STEP 1

Remove shipping plugs from pump ports. Some water
from factory testing may spill out.

STEP 2

Connect fittings supplied with the pump to the RV’s
plumbing. Use 1/2’ I.D. Flexible hose (preferably braided
or reinforced) to reduce vibration through the plumbing
system as shown on Fig. 1. Use hose clamps on the
slip-on barb hose connectors.

STEP 3

Slide rubber mounts fully into 4 mounting tracks.

STEP 4

Mount pump vertically, with pump head down or
horizontally in an accessible location. If mounting
vertically, motor up, attach motor mounts first then pump
head mounts, while supporting weight of pump.

STEP 5

Install inlet A and discharge B port connectors. Firmly
push slide clips C forward to lock port connectors in
place.

STEP 6

Install a Flojet strainer in an accessible location (for
inspection and cleaning) between the tank and pump
inlet.
This strainer or equivalent is required for pump warranty
to be valid.

STEP 1

Use 14 gauge stranded wire to 20’, 12 gauge to 50’,
from power source.

STEP 2

Use a 10-15 amp rated on-off switch on the (+) positive
(red) motor lead.

STEP 3

Install a 10 amp fuse protection on the positive lead.

FIG. 1

Note: To help reduce noise and vibration of the pump
through the system use flexible lines on the inlet and
outlet of the pump as shown above. Be sure to use
lines rated to not collapse under pump vacuum.

City Water

Inlet

Check

Valve

Flojet Inlet

Strainer

Water

Heater

Water

Tank