PLUMBING INSTALLATION

PLUMBING

The Bottled Water Dispensing System may 
also be placed in a pantry, closet, cellar or 
other location where a grounded electrical 
outlet is available.

Insert suction hose port 

fitting into pump module 

“IN” port and slide locking 

port clip in place.

Insert DC plug/connector into pump module “DC IN” port.

The connections for the float and power supply will require 

moderate force to insert fully.  This is a design feature 

that assures the connections are held securely after initial 

installation.  MAKE SURE PLUG / CONNECTOR IS INSERTED 

ALL THE WAY INTO THE CONNECTIONS.  FAILURE TO 

INSERT FULLY WILL LEAD TO POOR OPERATION OR NO 

OPERATION.

To install tube into 

“OUT” port. Push 

1/4” discharge

tubing all the way 

into quick

connect port

(as far as it will go)

To remove tube from “OUT” port:

1. 

Push tube all the way in

2. 

Hold gray ring against black 

port with finger or flat  tool

3. 

Pull tube out

Push clip up to lock

Insert float sensor switch plug/connector into pump 

module “SWITCH” port.

The connections for the float and power supply 

will require moderate force to insert fully.  This 

is a design feature that assures the connections 

are held securely after initial installation.  MAKE 

SURE PLUG / CONNECTOR IS INSERTED ALL THE 

WAY INTO THE CONNECTIONS.  FAILURE TO 

INSERT FULLY WILL LEAD TO POOR OPERATION 

OR NO OPERATION.

Select a cabinet large enough to accommodate the 5 gallon (19L) bottle and suction wand assembly. Place the 
pump module on the floor of the cabinet with on/off switch and suction tube facing out toward the cabinet doors. 
Position as close as possible to a
grounded electrical outlet and
place the five gallon bottle close to
the pump module without kinking the
suction hose.

Summary of Contents for 21000738A

Page 1: ...5000 Series Bottled Water System by www xylemflowcontrol com 2015 Xylem Inc All rights reserved Flojet is a trademark of Xylem Inc or one of its subsidiaries 81000453 Rev A 04 2015 ...

Page 2: ...he float switch on the end of the wand and turn on the pump This same float switch shuts off the system when the bottle is empty The wand has a built in back flow preventor valve that prevents water in the system from flowing back into the bottle or spilling while changing bottles The heart of the system is the main module that automatically fills an appliance or dispenses water through a faucet w...

Page 3: ...rt as far as it will go To remove tube from OUT port 1 Push tube all the way in 2 Hold gray ring against black port with finger or flat tool 3 Pull tube out Push clip up to lock Insert float sensor switch plug connector into pump module SWITCH port The connections for the float and power supply will require moderate force to insert fully This is a design feature that assures the connections are he...

Page 4: ...commercial brewer is unnecessary see below For installation on refrigerators with ice making and or water dispensing functions Do not use any external filtration devices These will cause the pump to over cycle possibly causing premature pump failure not covered under warranty If your refrigerator has factory installed internal filtration that must remain in place as part of the water line this too...

Page 5: ...bottle move bottle to an open area outside of cabinet Put new bottle next to empty bottle clean neck and cap area with detergent and remove cap Remove suction wand from empty bottle by lifting wand cap with a rocking motion and pull cap off bottle sliding suction wand out of the bottle and place directly into new bottle while sliding cap over new bottle neck SUCTION WAND INSTALLATION SANITIZE BOTT...

Page 6: ...r with a clean paper towel If using the optional Flojet faucet disconnect the tubing Remove the faucet immersing it in the water bleach solution for ten minutes Wash the faucet exterior with clean paper towel install the faucet and reconnect the tubing Place suction wand into clean empty pail B and dispose of solution in pail A 5 Refill the cleaned pail A with two 2 gallons of hot tap water 135 F ...

Page 7: ...to a grounded electrical outlet and place the five gallon bottle close to the Pump Module without kinking the suction hose The Bottled Water Dispensing System may also be placed in a pantry closet cellar or other location where a grounded electrical outlet is available Dual Inlet Bottled Water System Installation and Maintenance Instruction Insert To be released in near future B A C D F E Replacem...

Page 8: ...at appliance inlet Check for filter unit in line remove if present Check for internal filters in the refrigerator remove if present TROUBLESHOOTING WARRANTY Flojet warrants this product to be free of defects in material and or workmanship for a period of one 1 year after purchase by the customer from Flojet During this one 1 year warranty period Flojet will at its option and at no charge to the cu...

Reviews: