Installation of a
Second Station
Two FLO Home™ X5 can be connected to a separate or on
the same 40A circuit breaker via a junction . The first
charging station will automatically detect the second.
- Power splitting only works with the FLO Home™ X5.
- When 2 stations are connected to the same circuit breaker,
their output current will be limited to 16A each.
- The two FLO Home™ X5 will synchronize automatically after
the power is restored.
N
ote
After a power failure, when two stations are
powered from separate circuit breakers, they are
automatically configured in power sharing mode
for safety purposes.
To restore full power, follow these steps:
1. Disconnect the power from the 2 stations using
the 2 circuit breakers
2. Power the first station and wait for 10 seconds
3. Power the second station
Single circuit breaker setup
Dual circuit breaker setup