4.2Position of Junction Box
4
3Changing Position of Junction Box
The junction box can be rotated in a step of 45'
The procedure for changing the position of junction box are as follows:
I.Close the valves at the inlet and outlet and release the pressure;
2 . Unscrew and remove the four socket head screws that fasten the pump body;
3.Rotate the motor to the expected position and align the four screw holes
4.Installthe four socket head screws again and fasten them clockwise
5.open the valves at the inlet and outlet.