25
6.2 Description of Operation Menus
6.2.1 Abbreviated codes of menus
Level One Menu
Menu Codes and Description
Details
Measurement value
& status
*R- System Normal
*E- Signal Not Detected
*D- Adjusting Gain
M00 Flow Total
Net total
Positive total
Negative total
M01
Flow Rate
Flow rate & Flow velocity
M02 Heat (Optional function)
Heat total & temperature
difference (
Δ
T)
M03 Cool (Optional function)
Cool total & temperature
difference (
Δ
T)
M04 Status
Signal strength & quality
Sound velocity & Ratio
Transmission total time &
difference
Site information setting
M10 Pipe Settings
Pipe OD, thickness & Material
M12 Medium Settings
Water & other liquid
M13 Transducer setting
No need to set here
M14 Installation Space
Installation Space
Adjustment setting
M20 Damping
M21 Low Flow Cut off
Low Flow Cut off Value
M22 Zero Point Settings
Cut off Zero & Reset