10
Type-K Temperature Accuracy
± (1% of r 5.4
℉
[3
℃
])
Maximum voltage at Type-K input
60V DC or 24V AC rms
1. Note that this is the temperature range of the camera NOT the range for the supplied thermocou-
ple. Please do not exceed the specified range printed on the thermocouple label. To measure
higher or lower than the range of the supplied thermocouple, please use a Type-K thermocouple
rated for the desired range. Contact FLIR for additional information
10.7
Configuration Specifications
Set-up commands
Local adaptation of units, language, date
and time formats
Emissivity adjustment
3 presets plus a custom adjustment utility
(0.1 ~ 0.99)
Languages
Czech, Danish, Dutch, English, Finnish,
French, German, Greek, Hungarian, Italian,
Japanese, Korean, Norwegian, Polish, Por-
tuguese, Russian, simplified Chinese,
Spanish, Swedish, traditional Chinese,
Turkish
Firmware upgrades
User manageable (instructions included in
this user manual)
10.8
Image Storage Specifications
Storage media
eMMC 4G
Image storage capacity
50k images
Image file format
JPEG with spot temperature meta-data tag
10.9
Digital Camera Specifications
Resolution
2M pixels
Focus
Fixed
Field of View (FOV)
71° x 56° (adapts to IR lens)
10.10
Flashlight Specifications
Flashlight type
Bright LED
LED CCT
6500° K
LED CRI
70
Beam angle
± 20°