3 Oryx Installation
f. After download is complete, open the file to start the Spinnaker setup wizard.
g. Follow the steps in each setup dialog.
3. For Ethernet cards: Enable jumbo frames
a. In
Start->All Programs-> Point Grey Spinnaker SDK->SpinView
, right click on the Network Adapter and select
Adapter Configuration, then select IP Configuration.
b. Click Open Network Connections.
c. Click Change Settings.
d. Click on the Advanced tab and from the Settings list select Jumbo Packet.
e. Set the Value to 9014 Bytes and click OK.
3.3
Installing Your Oryx
1. Attach a Lens
Unscrew the dust cap from the lens holder to install a lens.
2. Connect the interface Card and Cable to the Camera
Plug the interface cable into the host controller card and the camera. The cable jack screws can be used for a secure
connection.
When the camera is first connected, the operating system automatically installs the camera driver. Camera drivers are
available with the Spinnaker SDK installation.
3. Plug in the GPIO connector
GPIO is used for power, trigger, serial input output, and strobe.
4. Configure IP Settings
By default, a dynamic IP address is assigned to the camera according to the DHCP protocol. If DHCP addressing fails, a
link-local address is assigned. If necessary, change the IP address of the camera to be on the same subnet as the NIC.
5. Confirm Successful Installation
Run the SpinView application:
Start->All Programs-> Point Grey Spinnaker->SpinView
The SpinView application can be used to test the camera's image acquisition capabilities.
Changes to your camera's installation configuration can be made using the SpinView application.
3.4
Powering Your Oryx
Power is provided externally through the GPIO interface: 12 - 24 V.
Power consumption is:
n
ORX-10GS-32S4 — 11.8 W (11.3 nominal)
n
ORX-10G(S)-51S5 — 12.3 W (11.7 W nominal)
n
ORX-10G-71S7 — 13.6 W (13.2 W nominal)