Camera Installation
•
Accessory cable 5-conductor for Alarm In/Out (optional)
•
PoE power supply or PoE switch, if used for system power.
•
Cat5e or Cat6 Ethernet cable for digital video and/or PoE for system power
•
Coaxial RG59U cables (BNC connector at the camera end) for analog video
•
Camera grounding strap, camera mount, electrical hardware, connectors, and tools
1.3.4
Camera Placement
For installations with multiple FB-Series ID cameras with on-board video analytics, the fields of view
of cameras should overlap in order to remove all dead zones in which a camera cannot see a target
“head to toe”. The camera’s on-board analytics must be calibrated to detect targets. Refer to
Analytics Setup—FB-Series ID Only, pg. 37
•
Install the camera at a height of approximately 4 m (13 ft) or more.
•
Typically direct the camera towards the ground with a tilt angle α within a range of 45° to 60°
while ensuring the field of view includes as little of the skyline as possible.
•
Ensure that cameras are mounted on stable mounts with minimal vibrations and maximal
resistance to wind.
•
The tilt angle (
α)
is the angle between vertical and the center of the camera field of view.
1.3.5
Mounting Accessories
The following mounting accessories are available from FLIR Systems, Inc. for installing the FB-
Series camera. For more information on available options, contact your FLIR sales representative to
request details on where to get the accessories you need.
α
4 m
Wall Mount Junction Box CB-WLBX-62
Pole Mount Junction Box CB-PLBX-62