Specifications 

General Specifications 

Display 

3-3/4 Digit LCD with 40 segment bargraph 

Functions 

Current (ACA, DCA) and Frequency (Hz) 

Polarity 

“-“ indicates negative polarity (positive polarity assumed) 

Current sensor 

Hall effect 

Overload 

Display indicates “1___” or “-1___” 

DCA zero adjust 

One-touch zero key (also used as a Relative function) 

Display rate 

2 readings/second (20 readings/second for bargraph) 

Battery 

Two 1.5V AA batteries 

Operating temperature 

4

0

F to 122

0

F (-10

0

C to 50

0

C) 

Operating Humidity 

< 85% RH 

Power consumption 

10mA DC approx. 

Weight 

6.2 oz. (190g) including battery 

Dimensions 

7.2 x 2.5 x 1.4” (183 x 63.6 x 35.6mm) (H x W x D) 

Jaw opening 

0.9” (23mm) 

Standards 

IEC 1010 Category III 300V, Category II 600V 

Range Specifications 

DC Current 

Resolution 

Accuracy (of rdg + digits) 

Overload Protect 

40A 

10mA 

±(1.0% + 2d) 

400A DC 

400A (0 to 150A) 

100mA 

±(1.0% + 2d) 

400A DC 

400A (150 to 200A) 

100mA 

±(2.2% + 2d) 

400A DC 

400A (200 to 400A) 

100mA 

±(4.0% + 2d) 

400A DC 

AC Current 

Resolution 

50/60Hz 

40Hz - 1kHz 

Overload Protect 

4A (0 to 500mA) 

1mA 

±(1.5% + 7d) 

±(2.0% + 7d) 

400A AC 

4A (500mA to 4A) 

1mA 

±(1.5% + 3d) 

±(2.0% + 4d) 

400A AC 

40A 

10mA 

±(1.5% + 3d) 

±(2.0% + 4d) 

400A AC 

100A (0 to 100A) 

100mA 

±(1.5% + 3d) 

±(2.0% + 4d) 

500A AC 

400A (100 to 200A) 

100mA 

±(2.2% + 3d) 

±(2.5% + 4d) 

500A AC 

400A (200 to 400A) 

100mA 

±(4.0% + 3d) 

±(5.0% + 4d) 

500A AC 

Frequency (Hz) 

Resolution 

Accuracy 

Sensitivity 

Overload Protect 

40Hz to 250Hz 

0.01 to 0.1Hz 

±(0.5% + 2d) 

3.0A 

500A AC 

250Hz to 10kHz 

0.1 to 1Hz 

±(0.5% + 2d) 

0.3A 

500A AC 