7.2
Electrical
Range
Specifications
Table 7.1
Voltage. Resolution of specifications in the 3 ¾-digit mode.
Mode
Range
Accuracy
DC
40.00
mV
0.05%+3d
400.0mV
0.05%+1d
4.000
V
40.00
V
400.0
V
1000
V
40
Hz
to
70
Hz
70
Hz
to
1
kHz
1
kHz
to
5
kHz
5
kHz
to
20
kHz
1
AC
40.00
mV
0.5%
+
2d
1.0%
+
4d
2.0%
+
4d
Unspecified
400.0mV
0.5%
+
2d
1.0%
+
4d
2.0%
+
4d
2.0%
+
20d
4.000
V
40.00
V
400.0
V
0.5%
+
2d
1.0%
+
4d
2.0%
+
4d
2
Unspecified
1000
V
0.5%
+
2d
1.0%
+
4d
Unspecified
Unspecified
1.
Below
10%
or
range,
add
10d
to
accuracy.
2.
Frequency
range
1k
to
2k
Hz
Input
protection:
1000
V
DC
or
1000
V
AC
RMS
Input
impedance:
mV:
1
M
Ω
,
<100
pF.
V:
10M
Ω
,
<
100
pF.
Bandwidth:
40
Hz
to
20kHz.
Minimum
resolution:
1
µV
in
the
40
mV
range.
CMRR/NMRR
(common/normal
mode
rejection
ratio):
V
AC:
CMRR
>
60
dB
at
DC,
50
Hz/60
Hz.
V
DC:
CMRR
>
100
dB
at
DC,
50
Hz/60
Hz.
NMRR
>
50
dB
at
DC,
50
Hz/60
Hz.
AC
conversion
type:
AC
coupled,
true
RMS
responding,
calibrated
to
the
sine
wave
input.
For
non
‐
sine
waves,
add
the
following
crest
factor
corrections:
For
a
crest
factor
of
1.4
‐
2.0,
add
1.0%
to
the
AC
accuracy.
For
a
crest
factor
of
2.0
‐
2.5,
add
2.5%
to
the
AC
accuracy.
For
a
crest
factor
of
2.5
‐
3.0,
add
4.0%
to