600.0 A
0.1 A
50 ~ 100 Hz
± (1.5% + 5 digits)
100 ~ 400 Hz
± (2.0% + 5 digits)
Induced error from adjacent current-carrying conductors: < 0.1A/A
Safety Category Rating: CAT III 1000 V & CAT IV 600 V AC
12.11
Resistance Specifications
Range
Resolution
Accuracy
600.0 Ω
0.1 Ω
± (1.0% + 3 digits)
6.000 kΩ
0.001 kΩ
Typical Constant Test Current: 0.1 uA
Open Circuit Voltage: 1.6 VDC
12.12
Continuity Specifications
Built-in beeper activates when measured resistance is < 30Ω and is silent
when measured resistance is > 480Ω. Between 30 and 480Ω the beeper can
be on or off.
Beeper response time: < 15 ms
12.13
Diode Specifications
Range
Accuracy
3.000 V
± (0.9 + 2 digits)
Test Current: 0.3 mA typical
Open Circuit Voltage: < 3.0 VDC typical
12.14
External (Flex) Clamp Adaptor — AC Current Specifications
Range
Frequency
Accuracy
30.00 A (100mV/A)
50 ~ 60 Hz (sine wave)
± (0.7% + 3 digits)*
300.0 A (10mV/A)
3000A (1mV/A)