Operating Instructions IRCamSafeEX-AXC
Ex d Enclosure for Infrared Cameras
6
AT-Automation Technology GmbH
4.2
Permitted Cable Glands and Connectors
There are two pressure-resistant, flameproof cable glands to connect the power supply line and
the data transmission line. Alternatively, pressure-resistant, flameproof connector systems can
be used. The cable glands and connectors are preassembled by the manufacturer. The enclosure
can also be supplied by the manufacturer with the connection cables already connected.
The following EX cable glands can be used with the protective enclosure.
Manufacturer
Reference
Size
Sheath diameter
A1 mm
Maximum
number of
single wires
Stahl
8163/2-20S/16-PXSS2K-M20
20s/16
3.1–8.7
15
Stahl
8163/2-20S-PXSS2K-M20
20s
6.1–11.7
15
Stahl
8163/2-20-PXSS2K-M20
20
6.5–14.0
15
Stahl
8163/2-20S/16-PX2K-M20
20s/16
6.1–11.5
15
Stahl
8163/2-20S-PX2K-M20
20s
9.5–15.9
15
Stahl
8163/2-20-PX2K-M20
20
12.5–20.9
15
Hummel
EXIOS Barrier 1.606.2000.50
20-1
6–12
8
Hummel
EXIOS Barrier 1.606.2000.51
20-2
9–16
10
Hummel
EXIOS Barrier 1.606.2000.52
20-3
12.5–20.5
15
The following EX connector systems can be used with the protective enclosure.
Manufacturer
Description
Reference
Stahl
Connector plug for power supply terminal
2-pin + PE
8591/16.-06-3.00
Stahl
Ethernet connector, 4-pin
8591/467-01-3022
Hawke
Panel jack for power supply terminal, 4-pin
N-BR1-M-B-P-X-0-3-X-A
Hawke
Panel jack for Ethernet connection, 8-pin
N-BR1-M-C-P-X-0-8-X-A
Labeling may change in line with current standard requirements as part of updates.
Installation work must only be carried out by specialist personnel
The cable glands and the connectors for the enclosure must be assembled by the manufacturer or
personnel authorized by the manufacturer.
4.3
Construction With Preassembled Connection Cables
Connection 1 (data link) is equipped with a fiber optic connection cable that has the following
properties:
Four-core fiber optic breakout cable for outdoor use, AT-V(ZN)Y(ZN)Y 4G50/125 OM2 or
62.5/125 OM1 (e.g. Helukabel 803348 with a sheath diameter of 8.5mm)
Four LC connectors preassembled on the enclosure interior; inside length of single wire: 450
mm
Summary of Contents for A310 ex Series
Page 1: ...User s manual FLIR A310 ex nbn Austria GmbH...
Page 2: ......
Page 3: ...User s manual FLIR A310 ex T559891 r AE 57789 57789 en US iii...
Page 4: ......
Page 6: ......
Page 24: ...Mechanical drawings 9 See next page T559891 r AE 57789 57789 en US 18...
Page 26: ...EC Type Examination Certificate 10 See next page T559891 r AE 57789 57789 en US 20...
Page 27: ......
Page 28: ......
Page 30: ......
Page 31: ......
Page 33: ......
Page 35: ......
Page 36: ......
Page 37: ...EC Declaration of conformity enclosure 14 See next page T559891 r AE 57789 57789 en US 31...
Page 39: ...Certiticate of conformity camera 15 See next page T559891 r AE 57789 57789 en US 33...
Page 40: ......
Page 49: ...This section contains the original manual from the manufacturer of the enclosure...
Page 99: ......