background image

DAPS440


7

  

Revision E, December 2009

 

Video Wiring Suggestions 

All shields should be grounded to the connector at the source, and floating at the 
display. 

Avoid routing video wiring parallel to: 

  AC wiring 

  Strobe wiring 

  DC motor supply cables 

  Inverter cabling 

  Or any other potential noise source. 

S-Video/Composite and Audio Wiring 

Recommended cable for s-video/composite and audio purposes is PIC 75 Ohm 
Coax, P/N V75268. This is a lightweight, flexible, and low signal loss cable which 
meets FAA flammability requirements of FAR 23.1359(d), FAR 25.853(a) and 
FAR 25.869(a)(4). 

 

Similar aviation coaxial cable can be used from other vendors, as well.  

Some aircraft are prone to AC noise - we recommend adding to the composite 
source a 75Ohm video isolation transformer such as Deerfield Laboratory, Inc. 
Part No. 162-1 (www.deerfieldlab.com, (650) 632-4090). In most cases this 
should be added to the video output of the source. 

Power and Ground Wiring 

22 AWG wire is recommended for Power and Ground applications. 

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for DAPS440

Page 1: ...DAPS440 Installation and Operation Manual Video Audio Switcher TECHNICAL SUPPORT 678 867 6717 or www FlightDisplay com All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...erved Flight Display Systems 1765 Grassland Parkway Alpharetta GA 30004 678 867 6717 Phone 678 867 6742 Fax sales flightdisplay com www flightdisplay com For the most current copy of all product manuals please visit our website at www flightdisplay com All manuals and user guides at all guides com ...

Page 3: ...Composite and Audio Wiring 7 Power and Ground Wiring 7 Pinout for High Density DB 15 8 Wiring Diagram 8 Troubleshooting Video Noise 9 Snow or Sweeping Lines 9 No power to Monitor or No video Input 9 Color Distortion 9 Technical Support Instructions for Continued Airworthiness Warranty Information Assembly Drawing 12 Index Log of Revisions 14 All manuals and user guides at all guides com ...

Page 4: ...witching is accomplished with a ground switching system The DAPS440 will support the installation of four independent switches at four different seat locations Each individual at each of the four seat positions can independently access up to four audio and video sources by pushing their button Every time the button is pushed the audio and video source will sequence through sources 1 2 3 and 4 For ...

Page 5: ... become necessary There are six mounting slots located on the sides of the housing Four holes are located at the four corners of the back and four holes are located two on each side of the flange It is sufficient to mount the display by two attach points It is recommended that you leave about inch of space around the unit for air circulation Audio Video inputs are paired and listed on the same sid...

Page 6: ...ghtweight flexible and low signal loss cable which meets FAA flammability requirements of FAR 23 1359 d FAR 25 853 a and FAR 25 869 a 4 Similar aviation coaxial cable can be used from other vendors as well Some aircraft are prone to AC noise we recommend adding to the composite source a 75Ohm video isolation transformer such as Deerfield Laboratory Inc Part No 162 1 www deerfieldlab com 650 632 40...

Page 7: ...eptacle female P N 748565 1 HD15F pins P N M39029 57 354 Wiring Diagram Pin Number Description 1 28VDC Power In 2 28VDC Ground In 3 N C 4 12VDC Power Out 5 12VDC Ground Out 6 12VDC Power Out 7 12VDC Ground Out 8 N C 9 12VDC Power Out 10 12VDC Ground Out 11 N C 12 Switch 4 13 Switch 3 14 Switch 2 15 Switch 1 All manuals and user guides at all guides com ...

Page 8: ... aircraft Be careful of inverter wiring which can also cause noise Stand off the wires if necessary If snow or sweeping lines persist it is possible that the ground is at an incorrect point in the aircraft Try moving the ground to another location No power to Monitor or No video Input Verify correct wiring Check the base receptacle connectors for possibly damaged pins Check that the video source i...

Page 9: ...y Systems 1765 Grassland Parkway Alpharetta GA 30004 Phone 678 867 6717 Fax 678 867 6742 Email sales flightdisplay com For further product information technical data and sample wiring diagrams please click on the Dealers section of our web site at www flightdisplay com Instructions for Continued Airworthiness The DAPS440 is designed not to require regular general maintenance All manuals and user g...

Page 10: ... Display Systems will upon receipt of the failed hardware remanufacture or replace the unit at our discretion Flight Display Systems will pay Ground Shipping charges for warranted items Charges for express shipment will be the responsibility of the sender This warranty is not transferable Any implied warranties expire at the expiration date of this warranty We shall not be liable for incidental or...

Page 11: ...12 Revision E December 2009 Assembly Drawing All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 12: ...r 2009 Index Coaxial Cable 6 Color Distortion 8 Continued Airworthiness 9 DB 15 7 Flammability 6 Noise 8 Power 8 Shields 6 Support 8 9 Warranty 10 Wiring 6 Diagram 7 Power and Ground 6 All manuals and user guides at all guides com ...

Page 13: ... A 01 25 2007 B 01 16 2008 8 Swapped pinout of Switch Inputs C 06 20 2008 8 Removed Remote Control Inoperable from troubleshooting D 04 14 2009 6 11 Updated specifications warranty info E 12 11 2009 12 Revised Assembly Drawing All manuals and user guides at all guides com ...

Reviews: