Setting-up and Powering a Color Filter Wheel

Assemble all components in one area before beginning this set up procedure. Refer to the next topic 
for installing filters into the Color Filter Wheels.

1. 

Plug the power supply cable into the Color Filter Wheel. 

2. 

Attach the USB cable between the Color Filter Wheel and your computer.

3. 

Plug the power supply cable into a wall socket or switched AC power strip.

4. 

Run FLI Filter to initialize the Color Filter Wheel and make control selections.

The following notes are provided to assist you with the FLI Filter Software:

•  The FLI Filter software should automatically recognize the type of Color Filter Wheel that is attached to your 

computer and display the correct number of filter positions. If the computer does not correctly identify this 

information, refer to the Troubleshooting topic later in this Guide for instructions.

•  Upon correct installation and installation of filters, you should initiate a Homing procedure. To do this, on the FLI 

Filter dialog, click Home. The Color Filter Wheel will move to display the zero position in the aperture. Verify the 

filter is positioned in the center of the Color Filter Wheel aperture. The filter pocket/cup in the aperture position is 

displayed at the bottom of the dialog. 

•  You can move the Color Filter Wheel to a particular filter pocket/cup position. To do so, on the FLI Filter dialog, click 

the button corresponding to the pocket/cup. The Color Filter Wheel will move to display the selected pocket/cup 

position in the aperture.

•  To rename a filter on the FLI Filter dialog, simply right click on the button corresponding to the filter name. On the 

displayed dialog enter the new name, then close the dialog.

•  To incrementally move the filter displayed in the Color Filter Wheel aperture, use the directional buttons (CW or 

CCW). The wheel moves in small steps in the selected direction.

Summary of Contents for CFW-1-5

Page 1: ...Color Filter Wheel User s Guide Engineering Excellence Because Your Image Depends On It Because Your Image Depends On It Engineering Excellence...

Page 2: ...FW 4 5 CFW 5 7 CFW 6 6 CFW 9 5 For information on FLI CenterLine Color Filter Wheels please visit our website at www flicamera com When differences between these products exist such as when replacing...

Page 3: ...lter Software 6 Setting up and Powering a Color Filter Wheel 7 Filter Installation CFW 2 7 8 Filter Installation CFW 1 5 CFW 1 8 CFW 6 6 8 Filter Installation CFW 5 7 9 Filter Installation CFW 4 5 CFW...

Page 4: ...lter Wheel order should include the following items Color Filter Wheel USB cable 15 long 12 volt power supply 5 64 Hex wrench for adapter pocket camera coupling O rings for each filter pocket cup of t...

Page 5: ...13 43 6 mm 13 Notes 1 Front to back thickness of the fi lter wheel excluding motor in inches mm 2 Filters are round unless followed by SQ indicating square 3 Typically the camera side of the fi lter w...

Page 6: ...the onscreen prompts for the installation instructions On screen prompts will indicate subsequent steps and the completion of the installation process Note Run the FLI Software Installation Kit befor...

Page 7: ...r to the Troubleshooting topic later in this Guide for instructions Upon correct installation and installation of filters you should initiate a Homing procedure To do this on the FLI Filter dialog cli...

Page 8: ...omputer and supply power to the Color Filter Wheel 9 Initiate a homing procedure Some Color Filter Wheels with a large aperture are designed for filter installation without the need to remove the cove...

Page 9: ...ter Wheel over so that the Multi Step Filter Retainers are Facing Up 6 Select one of the Filter Pockets to install a Filter and Remove both filter Retainers using a Philips Head Screw Driver 7 Careful...

Page 10: ...r Ledge accommodates the thickest Filter and the Thickest Filter Retainer Ledge accommodates the Thinnest Filter NOTE It is not necessary to remove the cover to install the filters 1 Remove both filte...

Page 11: ...the aperture 3 Snug the screws using the provided hex wrench The adapter should align itself during the snugging procedure Appendix A Troubleshooting Issue Remedy The computer does not correctly ident...

Page 12: ...ck over voltage reverse polarity connections or other environmental hazards is not covered under warranty 7 FLI will be the sole judge of what constitutes defects vs normal performance 8 FLI applicati...

Page 13: ...se boxes are designed to protect the products OR If you do not have the original shipping boxes obtain a rigid box that is at least 3 7 5 cm larger in all dimensions than the items A smaller box will...

Page 14: ...ion LLC 14 Return Addresses by Carrier UPS and Fed Ex Returns Finger Lakes Instrumentation Att Greg Terrance 7287 West Main St Lima N Y 14485 USPS Returns Finger Lakes Instrumentation Att Gregory Terr...

Reviews: