background image

SUMMARY

OPTIONS SELECTION

On the back of the thermostat, there are 3 selection switches  to set at

your preferences.

Temperature in °C or °F, time in 12 or 24 hours and Early Start function.

TO SET TIME AND DAY
Press on DAY, HOUR and MIN buttons to adjust time and day.

TO RECORD THE       (COMFORT) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using        or       button. Press on

button (2 to 3 seconds) until icon appears on display.

TO RECORD THE       (ECONOMY) SETPOINT TEMPERATURE
Select  chosen  setpoint  temperature  by  using      or      button.
Press on    button (2 to 3 seconds) until icon appears on display .

CHECKING GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
Adjust the setpoint temperature until heating indicator (        ) appears on

display.  Press on TEST button.  The test is conclusive if the warning light

(GFI) on thermostat is ON and power to the load is cut-off (          remain 

on  display  though).  If  these  events  do  not  occur,  check  the  installation.

Press on RESET button to reset the GFCI.

OPERATING MODES
To select an operating mode, use MODE button.
AUTO:

Runs the program.       or      shows temperature setting

and can override temporarily your programming up to the 

next program

MAN:

Maintains the selected temperature.       or      changes

the temperature setting.

Power-up

When  power  is  applied  for  the  first  time,  the

display  must  show  the  time  00:00,  the  floor

temperature and the manual mode icon (       ).

Other information might show up on the display if

installation  is  defective  or  does  not  comply  with

the instructions. The warning light (GFI) must be

off.

The message L0 or HI will appear on the display

if the temperature sensor is defective or the tem-

perature  is  below  0  °C  (32  °F)  or  higher  than 

60 °C (140 °F). Also, the heating indicator will be

present  on  display  and  the  relay  will  be  closed

(current going in the load).

Checking ground fault circuit interrupter (GFCI)

Adjust  the  setpoint  temperature  until

heating  indicator  (        )  appears  on

display. Press on TEST button. The test is

conclusive if the warning light (GFI) on the

thermostat is ON and power to the load is

cut-off. If these events do not occur, check

the installation. Press on RESET button to

reset the GFCI.

If the GFCI test fails: 

Check  the  load  wires.  The  thermostat

must be in heating mode to carry out the

test (heating indicator ON).

The  GFCI  test  should  be  carried  out

monthly. If the test fails, cut off the electric

power  to  the  heating  system  and    call

customer service or return the thermostat

to  your  supplier  for  verification.  If  the

warning  light  comes  on  during  normal

operation,  cut  off  power  to  the  heating

system and have an electrician verify the

installation.

LS240P

3840 W (NI) @ 240 VAC

LS240P

3840 W (NI) @ 240 VAC

INSTALLATION

This  thermostat  is  designed  to  control  floor  electric  heating  systems.  The

resistive  load  must  not  exceed  3840  watts  (NI)  @  240  VAC  (16  A).  The

thermostat is equipped with a ground fault circuit interrupter (GFCI) and therefore

the isolation of the line and load are required for operation. During a ground fault,

the two lines of the load will be cut off from the 240 V line. Connect thermostat as

shown on diagram.

This thermostat is an electrical product and must be installed in conformity with

the national and/or local Electrical Code. The installation must be performed by

qualified personnel where required by law.

This thermostat is designed to be used with a heating system with circuit breaker.

PARTS INCLUDED

- One (1) LS240P (240 VAC) thermostat

- Two (2) 6-32 screws

- Four (4) solderless connectors (for copper wire)

- One (1) Temperature sensor with a 15 foot extension

TURN  OFF  POWER  OF  THE  HEATING  SYSTEM  AT  THE  MAIN  POWER

PANEL TO AVOID ELECTRICAL SHOCK.

Keep air vents of the thermostat clean

and free from obstructions.

1) Connecting wires and mounting thermostat

Connect the rear thermostat wires  to the 240 V LINE and to the load using sol-

derless connectors for copper wires. See schematic diagram.

u

u

u

u

u

u

Push the excess wire back into the electrical box to prevent interference with

the thermostat. Secure the thermostat using two (2) 6-32 screws. Once the ther-

mostat is properly installed, return power to heating system. 

NOTE:

All cables and connections must conform to the local electrical code.

WARNING: 

Special  CO/ALR  solderless  connectors  must  be  used  when

connecting with aluminum conductors.

2) Connecting temperature sensor wire

Connect the temperature sensor wire to the

two  lower  screws  of  the  terminal  block  at

the back of the thermostat (no polarity need

to be respected).  The wire must  pass out-

side  the  electrical  box  and  follow  the  wall

down  to  the  floor.  Install  the  sensor  wire

between two runs of cable, at a distance of

30 to 60 cm (1 to 2 feet) within the heating

zone  in  a  neutral  location,  away  from  any

source  of  heat  or  cold.  Do  not  cross  the

probe wire over  the heating cable.  Secure

the sensor to the floor with hot glue.  It will

be  necessary  to  recess  the  sensor  in  the

floor so it is at the same level as the heating

cable.

240 VAC

VAC

240

60 HZ

920-111-013-00-1-B     LS240P0212A -  Printed in China   1/2

OPERATING MODES

The LS240P has two (2) operating modes.

M

ANUAL

(       )

This mode allows you to maintain a constant temperature of the floor.

1- To activate this mode, press on Mode button to display the       icon.
2- Set the desired temperature using the              buttons or select the

pre-programmed        or      or        settings.

(To select the      setting, press on       and       simultaneously.)

AUTO

MATIC

(        )

This mode executes your own programming.

To  activate  this  mode,  press  on  Mode  button  to  display  the      icon.

The        or        icon indicates which temperature setting is used. Also, the icon

of the program number will be shown.

LS240P

Programmable Electronic 

Thermostat (240 volts)

Reviews: