6
© 2016 OJ Electronics A/S
Type FLP35-120/240GA
English
Display
I want to choose the information to be shown on the
thermostat display.
To do so, you must:
1
Press the
OK
button twice to activate the menu.
2
Press the
Up
or
Down
buttons until the
Settings
option
flashes.
3
Press the
OK
button.
4
Press the
Up
or
Down
buttons until the
Display
option
flashes.
5
Press the
Up
or
Down
buttons to select whether you wish to:
- display the
Clock
or not (On/Off),
- display the
Set temperature
or not (On/Off).
You can also decide whether the temperature displayed is:
- the Room temperature,
- the Floor temperature (if a floor sensor is used), or
- the Regulator temperature.
6
Press the
OK
button to confirm the settings as you work your
way through the various options in the
Display
submenu.
7
Select
Exit
to exit the option.
Factory settings:
- TIME: ON
- Set temp.: ON
- Floor temperature is shown
FLOOR
SETTINGS
TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
On/Off
On/Off
Room/floor/regulator
Factory Reset
I want to return to the factory settings.
To do so, you must:
1
Press the
OK
button twice to activate the menu.
2
Press the
Up
or
Down
buttons until the
Settings
option flashes.
3
Press the
OK
button.
4
Press the
Up
or
Down
buttons until the
Factory Reset
option
flashes.
5
Press the
OK
button. A submenu will appear.
6
Press the
Up
or
Down
buttons until the
Reset
option flashes.
7
Press the
OK
button.
8
Select
Exit
to exit the option.
Please note:
The date and time cannot be reset.
SETTINGS
TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
RESET
EXIT
Exit Menu
I want to exit a menu.
To do so, you must use the Exit option:
The various menus and submenus contain an
Exit
option.
1
Press the
Up
or
Down
buttons until
Exit
flashes.
2
Press the
OK
button. You may have to repeat steps 1 and 2 to
return to the final
Exit
option.
Please note:
When you activate a menu, the menu item last se-
lected will begin flashing. This allows you to view the latest setting.
If, for example, you activate the
Mode
menu,
Man. mode
will flash
if you used
Man. mode
the last time.
This principle also applies to current temperature/time settings.
When you enter the various menus, they always display the value
that was last selected. This allows you to check the current set-
tings.
Should you enter a menu by mistake, you can exit it again without
changing the setting by simply confirming the current setting, i.e.
by clicking the
OK
button.
Error Messages
E0 = Internal failure. Replace thermostat.
E1 = Internal sensor defective or short-circuited.
Replace thermostat.
E2 = External sensor defective or short-circuited.
Check external sensor.
Factory Settings for Automatic 5:2 Program
Days 1-5 (Monday - Friday)
Event
Time
Temperature
Morning
6:00 a.m. - 8:00 a.m.
77 °F / 25 °C
Out
8:00 a.m. - 4:00 p.m.
68 °F / 20 °C
Home
4:00 p.m. - 10:00 p.m.
77 °F / 25 °C
Night
10:00 p.m. - 6:00 a.m.
68 °F / 20 °C
Days 6-7 (Saturday - Sunday)
Event
Time
Temperature
Day
8:00 a.m. - 11:00 p.m.
77 °F / 25 °C
Night
11:00 p.m. - 08:00 a.m.
68 °F / 20 °C
AM