background image

5

© 2016 OJ Electronics A/S

Type FLP35-120/240GA   

 English

Please note:

 Usually, the electrician who installed the thermostat 

will have set the correct time and day of the week.

SETTINGS

DAY

MON

FRI

TUE
SAT

WED
SUN

THU

Readout

I want to know the amount of time (in percentage) during 

which the heating was turned on within a certain period.

To do so, you must:

1

  Press the 

OK

 button twice to activate the menu.

2  

Press the 

Up

 or 

Down

 buttons until the 

Settings

 option flashes.

3

  Press the 

OK

 button.

4  

Press the 

Up

 or 

Down

 buttons until the 

Readout

 option flashes. 

5

  Press the 

Up

 or 

Down

 buttons to the select the period of inter-

est: 

2 days

30 days

 or 

365 days.

 

 The percentage of time that 

the heating was turned on will then be indicated in the upper 
part of the display. 

The 

Readout 

submenu also contains information about the 

Software

 version and the type of control (Room, Floor, Regu-

lator or Room limit) selected for the 

Application

(See Application for more information).

SETTINGS

READOUT

2 DAYS
30 DAYS
365 DAYS
SOFTWARE
APPLICATION
EXIT

Offset Temperature 

I want to adjust the difference in temperature between 

the thermostat and my room thermometer.

 

To do so, you must:

1  

Press the 

OK

 button twice to activate the menu.

2  

Press the 

Up

 or 

Down

 buttons until the 

Settings

 option flashes.

3  

Press the 

OK

 button.

4

  Press the 

Up

 or 

Down

 buttons until the 

Offset Temp

 option 

flashes. 

5  

Press the 

Up

 or 

Down

 buttons to set the offset temperature (in 

steps of 1°).

6

  Press the 

OK

 button.

7

   Select 

Exit

 to exit the option.

Offset is used to compensate for any difference between the 
thermostat and a room thermometer. It is possible to adjust the 
offset by up to +/- 10 °C or +/- 18 °F. Once the offset has been set 
correctly, the thermostat will display the same temperature as the 
thermometer. 
If, for example, the thermostat shows 1° too much, the offset 
should be set to 1°. The temperature will then be set 1° lower.

SETTINGS

OFFSET TEMP

Application

I want to select the type of temperature control.

 

To do so, you must:

1

  Press the 

OK

 button twice to activate the menu.

2

   Press  the 

Up

 or 

Down

 buttons until the 

Settings

 option flashes.

3

  Press the 

OK

 button.

4

  Press the 

Up

 or 

Down

 buttons until the 

Application

 option 

flashes. 

5

  Press the 

Up

 or 

Down

 buttons to select one of the four types 

of control: 

Room: 

The built-in room sensor is used.

 

Only room tempera-

ture is controlled. 

Floor:  

The floor sensor is used. Only floor temperature is 

controlled. If you choose this option, you must set a maximum 
and minimum temperature for the floor sensor. 

Regulator: 

The thermostat functions as a simple regulator and 

no sensors are used. 

Room limit: 

The thermostat controls room temperature while 

using the external temperature sensor as a limit sensor. If you 
choose this option, you must set a maximum and minimum 
temperature for the limit sensor, so that the thermostat will 
switch the heating on or off if the floor temperature  reaches 
the maximum or minimum temperature respectively. This can, 
for instance, be used to avoid excessively high temperatures 
on wooden flooring (maximum limit) or excessively cold tem-
peratures on tiled/stone flooring (minimum limit).

6

  Press the 

OK

 button.

7

   Select 

Exit

 to exit the option.

Please note:

 Usually, the electrician who installed the thermostat 

will have selected the correct type of temperature control for your 
application.

ROOM
FLOOR
REGULATOR
ROOM LIMIT

SETTINGS

TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT

Fact

or

y setting: Monday

Fact

or

y setting: 0.0 °F

Fact

or

y setting: FL

OOR

Summary of Contents for FLP35-120GA

Page 1: ...temperature is reached at the required time After three days the adaptive function has learned when the heating must be switched on First Time Settings The first time you turn on the thermostat time...

Page 2: ...Auto mode AUTO OVERRIDE MAN MODE MODE SCHEDULE PROGRAM SETTINGS EXIT Step 2 Choose the weekly schedule for your program You have the following options 5 2 will give you 5 days Monday to Friday with t...

Page 3: ...s 7 Press the OK button 8 Select Exit to exit the option Please note The adaptive function is only related to the 4 event program and only works in connection with going from one event to another wher...

Page 4: ...e Up or Down buttons until the required unit C F flashes 6 Press the OK button 7 Select Exit to exit the option Please note Temperatures are displayed in Celsius with a resolu tion of 0 5 degree and i...

Page 5: ...nce the offset has been set correctly the thermostat will display the same temperature as the thermometer If for example the thermostat shows 1 too much the offset should be set to 1 The temperature w...

Page 6: ...the OK button 8 Select Exit to exit the option Please note The date and time cannot be reset SETTINGS TIME DAY CHILDLOCK C F APPLICATION OFFSET TEMP READOUT ADAPTIVE DISPLAY FACTORY RESET EXIT RESET...

Page 7: ...choisir l horloge de 12 heures ou appuyez sur le bouton vers le bas pour choisir l horloge de 24 heures et appuyez sur OK pour confirmer R glez l heure actuelle en utilisant les boutons Up hausse ou...

Page 8: ...ifier chaque mois le disjoncteur de fuite la terre int gr V rification du disjoncteur de fuite la terre int gr La v rification ne peut s effectuer que si le thermostat active le chauffage R glez le po...

Page 9: ...activer le menu 2 Appuyez sur les boutons Up hausse ou Down baisse jusqu ce que l option Settings r glages clignote 3 Appuyez sur le bouton OK 4 Appuyez sur les boutons Up hausse ou Down baisse jusqu...

Page 10: ...oir la page 2 pour les instructions MAN MODE MODE D rivation temporaire Je veux r gler temporairement une temp rature de confort pour un seul v nement par exemple si un jour je ne suis pas au travail...

Page 11: ...e sera alors ajust e 1 plus bas SETTINGS OFFSET TEMP Application Je veux choisir le type de contr le de la temp rature Pour le faire vous devez 1 Appuyez deux fois sur le bouton OK pour activer le men...

Page 12: ...les Pi ce La sonde de pi ce int gr e est utilis e Seule la tem p rature de la pi ce est contr l e Sol La sonde au sol est utilis e Seule la temp rature du sol est contr l e Si vous choisissez cette op...

Page 13: ...nts Si vous ouvrez un menu par erreur vous pouvez en sortir sans changer le r glage en confirmant simplement le r glage courant c d en appuyant sur le bouton OK Messages d erreur E0 Panne interne Remp...

Page 14: ...que encienda el termostato ser necesario ajustar la hora y el d a Parpadea la hora Ajuste la hora actual con los botones Up Arriba o Down Abajo Despu s pulse el bot n OK Aceptar para confirmar la hora...

Page 15: ...Para hacerlo ser necesario realizar los 3 pasos sigui entes Paso 1 Seleccione el control de temperatura autom tico 1 Pulse el bot n OK para activar el men 2 Pulse los botones Up o Down hasta que parp...

Page 16: ...r en el futuro para este evento Ejemplo Si usted cambia la temperatura para el martes en la ma ana mientras el termostato ejecuta un programa 5 2 la nueva temperatura se aplicar a todas las ma anas de...

Page 17: ...e 4 eventos deber selec cionar Auto La p gina 2 incluye instrucciones MAN MODE MODE Anulaci n temporal Deseo establecer temporalmente una temperatura de confort para un solo evento por ejemplo no voy...

Page 18: ...icaci n para obtener m s informaci n SETTINGS READOUT 2 DAYS 30 DAYS 365 DAYS SOFTWARE APPLICATION EXIT Compensaci n de temperatura Deseo ajustar la diferencia en temperatura entre el termostato y mi...

Page 19: ...la temperatura ambiente la temperatura de piso si se utiliza un sensor de piso o la temperatura del regulador 6 Pulse el bot n OK para confirmar los ajustes mientras avanza a trav s de las diferentes...

Page 20: ...nterno Cambie el termostato E1 El sensor interno est defectuoso o en cortocircuito Cambie el termostato E2 El sensor externo est defectuoso o en cortocircuito Inspec cione el sensor externo Ajustes de...

Reviews: