1
© 2016 OJ Electronics A/S · ® The OJ trademark is a registred trademark belonging to OJ Electronics A/S
Easy2Use
Setting Time ............................................................................... 4
Setting Day ................................................................................. 4
Read Out .................................................................................... 5
Offset Temperature.................................................................... 5
Application ................................................................................. 5
Display ........................................................................................ 6
Factory Reset ............................................................................. 6
Exit Menu ................................................................................... 6
Error Messages ......................................................................... 6
Type FLP35-120/240GA
English .................. 1
Français ................ 7
Español ............... 14
67237B 01/16 (L
O
A)
© 2016 OJ Electr
onics A/S
U S E R M A N U A L
Contents
Introduction
The thermostat can switch on your heating system at predeter-
mined times on different days of the week. For each day of the
week, you can set individual temperatures for 4 periods, called
events. The thermostat comes with a default schedule suitable for
most installations. Unless you change the settings, the thermostat
will operate in compliance with the default schedule. Lowering the
temperature when the home is unoccupied will reduce your energy
costs without reducing comfort.
Furthermore, the thermostat features an adaptive function that
automatically changes heating period start times so as to ensure
that the required temperature is reached at the required time. After
three days the adaptive function has learned when the heating
must be switched on.
First Time Settings
The first time you turn on the thermostat, time and day must be
set. The number
12
will flash; select
12
for 12-hour clock or use
down arrow to select the 24-hour clock and press
OK
to confirm.
Set the current time using the
Up
or
Down
buttons. Then press
the
OK
button to confirm the time. The day of the week will then
flash. Select the current day using the
Up
and
Down
buttons.
Press the
OK
button. The thermostat is now ready for use and will
control your heating according to the pre-programmed 4-event
schedule (see Factory Settings for Automatic 5:2 Program).
Ground Fault Circuit Interrupter (GFCI)
The thermostat has a built-in GFCI that ensures personal safety
in case of ground faults. It is important that the GFCI is checked
monthly.
Up button
OK button
Down button
Standby button
Reset GFCI
GFCI test button
Type FLP35-120/240GA
English
Introduction ................................................................................ 1
First Time Settings .................................................................... 1
Ground Fault Circuit Interrupter (GFCI) ................................... 1
4-Event Program ........................................................................ 2
Quick Set Temperature ............................................................ 3
Adaptive Function ...................................................................... 3
Manual Mode ............................................................................. 3
Temporary Override ................................................................... 3
Child Lock .................................................................................. 4
Temperature Unit ....................................................................... 4