Moving and handling  

When moving the unit please ensure the two side handles are used. 

 

 

 

 

 

 

 

Before moving the unit to another location ensure the unit is turned off and the electrical supply is 
disconnected from the supply and the unit. 

 

Maintenance

  

 

 

 

 

 

During fault finding diagnostics and maintenance, it may be necessary to remove panels, which 
expose the dangers of electrical equipment. Only qualified personnel who are fully trained, aware and 
equipped to repair this equipment should complete such work. 

Isolate the unit from the mains electrical supply before opening control panels or removing any 
exterior panel. 

Never alter settings (apart from temperature set point) without first consulting Flexmort. 

 

General Maintenance 

• 

Clean CuddleBlanket chiller metal surfaces with a clean damp cloth. 

• 

Clean plastic surfaces with any plastic safe cleaner or disinfectant.  

Summary of Contents for HC170

Page 1: ...dleBlanket System for the Cooling of a Single Deceased Model designation HC170 Product Type Mortuary Cooling System THIS IS NOT A MEDICAL DEVICE Please read this manual before use www flexmort com 44...

Page 2: ...incorrect installation commissioning or operation Note The machine contains powered electrical devices and moving parts System components 1 sturdy plastic storage carry case with metal closures 1 main...

Page 3: ...neck We recommend placing a sheet over the deceased first Then use another sheet over the cooling pad before using the supplied insulated duvet This will help with cleaning and any condensation that m...

Page 4: ...culating fluid to this temperature The temperature of the fluid is shown by the red display and the green shows the set point 7 Turning off the system Switch off the unit at the black rocker switch re...

Page 5: ...s sounding and the red LED is illuminated Check the connection of the hose to the CuddleBlanket Refer to section 2 Check that the hose or cooling pad are not kinked or deformed Check that there is flu...

Page 6: ...all measurements are approximate Overall chiller unit dimensions 365mm x 249mm x 349mm Cooling pad dimensions 100cm x 70cm Weight 11kg drained Unpacking and Positioning Unpacking the CuddleBlanket Bef...

Page 7: ...ting hot exhaust air will adversely affect the performance of the coolant Symbols Identifying Marks and Warning Lamps Compliance CE compliant EMC LV compliant This cooler complies with current Europea...

Page 8: ...ecessary to remove panels which expose the dangers of electrical equipment Only qualified personnel who are fully trained aware and equipped to repair this equipment should complete such work Isolate...

Page 9: ...of equipment End of service life UK WEEE Regulations 2006 This equipment has been designed using recyclable and RoHS compliance standard parts where design conditions permit Please read the informati...

Reviews: