Unit operation modes
The unit has two ventilation modes:
Regeneration.
The unit operates in reversible mode
with heat and humidity regeneration in two cycles, 70
seconds each.
Ventilation.
The unit operates in permanent supply or
extract mode at set speed. In case of two units operating
in this mode one unit operates in supply and the other
one in extract mode.
Cycle I.
$VZDUPVWDOHH[WUDFWDLUȵRZVWKURXJKWKHFHUDPLF
regenerator, it heats up and moisturizes the regenerator
DQGWUDQVIHUVXSWRbRIKHDWHQHUJ\
In 70 seconds as the ceramic regenerator gets warmed
the unit is switched to supply mode.
Cycle II.
)UHVKLQWDNHDLUIURPRXWVLGHȵRZVWKURXJKWKHFHUDPLF
regenerator, absorbs accumulated moisture and is
heated up to the room temperature.
In 70 seconds as the ceramic regenerator gets cooled
down, the unit is switched to air extract mode and the
cycle is renewed.
In this operation mode, in case if two units are installed
each of them operates two cycles in opposite phases.
While one unit operates in air supply mode the other
one operates in air extract mode.
AIR EXTRACT
AIR SUPPLY
Example: