We reserve the right of changing these instructions without special prior notification
13
4.3. Manipulation with automatic
equipment
Putting on and of the sanitary water preparation
The boiler is switched on by means of the main switch (7),
for switching on, the switch should be put in the position 1.
Upon switching on a desired water temperature in boiler is
displayed for 5 seconds, signalization of sanitary water
preparation is twinkling (8). Upon 5 seconds real
temperature of sanitary water outlet is displayed (1); if there
is no requirement for sanitary water, the signalization lamp
of sanitary water preparation (8) is switched off.
By switching the switch (7) to the position 0, the sanitary
water preparation is put off. The entered desired
temperature of sanitary water shall be stored.
Adjustment of desired temperature of sanitary water
By pressing the key for tem
perature adjustment (6
) the
desired warm water temperature appears, the signalization
lamp of sanitary water preparation (8) is twinkling. By
repeated pressing upwards or downwards it is possible to
increase or decrease the desired sanitary water
temperature. When the temperature is adjusted it is
sufficient to wait for 5 seconds (signalization lamp of
sanitary water preparation (8) does not twinkle) in order that
the boiler memorizes a new temperature.
Use of sanitary water
If there is a need for sanitary water, the signalization lamp of
sanitary water preparation turns on (8) and the temperature
of warm water outlet displays. Signalization of operation
degree of heaters (2) displays and by turning on lamps it is
shown whether one group of heaters is in operation, two or
all three groups.
The boiler automatically controls a heater operation degree.
Putting on central heating
By switching the switch (5) to the position 1, the central
heating system is switched on. Upon switching on a desired
water temperature in boiler is displayed for 5 seconds,
signalization of boiler operation is twinkling (3). Upon 5
seconds real temperature in the boiler is displayed (1); if the
current temperature in boiler meets the desired one, the
signalization lamp of boiler operation (8) is switched off.
Adjustment of desired temperature of central heating
By pressing the key for temperature adjustment (4) the
desired temperature in the boiler appears, the signalization
lamp of boiler operation (3) is twinkling. By repeated
pressing upwards or downwards it is possible to increase or
decrease the desired sanitary water temperature. When the
temperature is adjusted it is sufficient to wait for 5 seconds
(signalization lamp of boiler operation (8) does not twinkle)
in order that the boiler memorizes a new temperature.
Segment of control panel
Segment of control panel